2 General Operating Information
46 Keysight U2020 X-Series User’s Guide
Table 2-3 Additional Instrument Setup tab settings description
Item Available settings
Trace Setup
Ad vanced:
Set the trace reference levels to be used in the calculation of transition durations and occurrences. This allows
transition measurements between non-standard reference levels.
Set the trace reference level to be used in the calculation of pulse durations. This allows pulse duration measurements
between non-standard reference levels.
Gate Setup
Set the gate start time and length.
The gate start time is relative to the trigger event. Positive values set a measurement gate to a maximum time of 1 second
after the trigger. Negative values set a measurement gate to a maximum time of 1 second before the trigger.
Refer to “Measurement Gates” on page 78 for more information.
Corrections
Set the frequency-dependent offset (FDO) which compensates for frequency-related changes in the response of your
test system. The BenchVue Power Meter application can store 10 FDO tables with 512 frequency points each.
Set the gamma and S-parameter corrections. The BenchVue Power Meter application can store 10 gamma/S-parameter
tables with 1024 magnitude-phase pairs each. Also refer to “Simplified Measurement Path” on page 74 for the above
corrections.
Measurement Setup
Ad vanced:
Enable alerts to detect when a measurement has crossed over a predefined upper and/or lower limit value. Refer to “Limit
Checking Application Example” on page 79 for more information.
Trigger Setup
Ad vanced:
Set the input impedance for the external TTL trigger to Low (50 Ω) or High (100 kΩ).
Enable the trigger output where a TTL level high is produced at the Trig Out connector when the U2020 X-Series is
triggered.
Enable the 10 MHz timebase.
Additional Instruments
View all connected instruments and select any instrument to use on the BenchVue Power Meter application. You can
connect up to 15 instruments per BenchVue Power Meter application.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight U2020 X Series and is the answer not in the manual?

Keysight U2020 X Series Specifications

General IconGeneral
BrandKeysight
ModelU2020 X Series
CategoryAccessories
LanguageEnglish

Related product manuals