-Green LED
The green LED will flash as described below under the following
conditions:
Standby Condition (powered by AC and battery backup):
The LED will be constantly on.
Standby Condition (powered by only battery backup):
The LED will flash every 60 seconds.
Smoke Alarm Memory Condition: The LED will flash
every second during alarm. When the alarm condition
goes away, the originating alarm unit will flash the LED
every 16 seconds until the test/reset button is pressed,
thus resetting the alarm.
Initiating Alarm condition: 1 second flash rate during the
alarm, which indicates this unit initiated the alarm.
Trouble Fault/Error mode: 1/2 second flash rate (AC
powered only). Helps owner locate the mysterious
chirping unit
HUSH MODE Condition: The LED will flash every 2
seconds while the alarm is in HUSH mode.
Operating Instructions