Chapter 7 List of Parameters
64
Function
code
Name
Descriptions
Unit
Factory setting
Modif.
Setting
range
A5.14
Speed→Torque
switching point
0%~+300.0% Initial torque
0.1%
100.0%
X
0~3000
A5.15
Speed/torque
switching delay
time
0~1000mS
1
0
X
0~1000
A5.16
Reference torque
filtering time
0~65535mS
1ms
0
X
0~65535
A5.17
ACR-P
1~5000
1
1000
O
1~5000
A5.18
ACR-I
0.5~100.0mS
0.1
8.0
O
5~1000
Group A6.Control terminals parameters
A6.00
Input terminal
X1 function
selection
0:No function
1:Forward
2:Reverse
3:Forward jog operation
4:Reverse jog operation
5:3-wire operation control
6:External RESET signal input
7:External fault signal input
8:External interrupt signal input
9:Drive operation prohibit
10:External stop command
11:DC injection braking command
12:Coast to stop
13:Frequency ramp up (UP)
14:Frequency ramp down (DN)
15:Switch to panel control
16:Switch to terminal control
17:Switch to communication control
mode
18:Main reference frequency via AI1
19:Main reference frequency via AI2
20:Main reference frequency via AI3
21:Main reference frequency via DI
22:Auxiliary reference frequency
invalid
23:Auxiliary reference frequency via
AI1 (Reserved)
24:Auxiliary reference frequency via
AI2 (Reserved)
25:Auxiliary reference frequency via
AI3 (Reserved)
26:Auxiliary reference frequency via
1
1
X
0~100