EasyManua.ls Logo

Kinco KS Series - Page 18

Kinco KS Series
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
K
K
K
K inco
inco
inco
inco -K
-K
-K
-K S
S
S
S series
series
series
series
18
HSC0
HSC0
HSC0
HSC0 HSC1
HSC1
HSC1
HSC1 HSC2
HSC2
HSC2
HSC2 HSC3
HSC3
HSC3
HSC3 Description
Description
Description
Description
SM141.0 SM151.0 SM161.0 SM171.0 Use multiple preset value:0=No. 1=Yes.
SM141.1 SM151.1 SM161.1 SM171.1
Preset value type:0=Absolute value. 1=Relative
value.
SM141.2 SM151.2 SM161.2 SM171.2
Preset value comparison interrupt ( CV=PV ) cyclic
execution.
0=No. 1=Yes.
Note:Only valid when preset value is relative value.
SM141.3 SM151.3 SM161.3 SM171.3 Reserved
SM141.4 SM151.4 SM161.4 SM171.4
Update multiple PV segment and preset value:0=No.
1=Yes
SM141.5 SM151.5 SM161.5 SM171.5 Reset interrupt variable:0=Yes. 1=No.
SM141.6 SM151.6 SM161.6 SM171.6 Reserved
SM141.7 SM151.7 SM161.7 SM171.7 Reserved
HSC0
HSC0
HSC0
HSC0 HSC1
HSC1
HSC1
HSC1 HSC2
HSC2
HSC2
HSC2 HSC2
HSC2
HSC2
HSC2 Description
Description
Description
Description
SMW142 SMW152 SMW162 SMW172
Starting value of preset value table It is offset
corresponding to VB0),it must be odd value.
It needs to pay attention that not all the control bits of the control byte is suitable for all operation mode. For
example, Counting direction and Write counting direction in HSC can be only used in mode 0,1 and 2
(Single-phase up/down counter
with internal direction control),if the operation mode is with external direction control, then these two bits
will be ignored.
The control byte, current value and preset value are 0 by default after power on.
Status
Status
Status
Status Byte
Byte
Byte
Byte
In SM area, each high-speed counter has a status byte, which indicates the current status of high speed
counter.
HSC0
HSC0
HSC0
HSC0 HSC1
HSC1
HSC1
HSC1 HSC2
HSC2
HSC2
HSC2 HSC3
HSC3
HSC3
HSC3 Description
Description
Description
Description
SM36.0 SM46.0 SM56.0 SM1 2 6.0 Reserved
SM36.1 SM46.1 SM56.1 SM1 2 6.1 Reserved
SM36.2 SM46.2 SM56.2 SM1 2 6.2 Reserved
SM36.3 SM46.3 SM56.3 SM1 2 6.3 Fault in multiple PV value table:0=No,1=Yes

Other manuals for Kinco KS Series

Related product manuals