Kinco FD5P series AC servo system
Kinco Electric (shenzhen) Ltd.
en.kinco.cn

Table of Contents

Questions and Answers

  • W
    william20Aug 11, 2025
    What to do if signal reflects at the end of Kinco Controller transmission line?
    • B
      Bruce JacksonAug 11, 2025
      When using Kinco Controller and experiencing signal reflection at the end of the transmission line due to a high 485 communication rate and long communication distance, connect a 120? terminal resistor in parallel at the beginning and end of the communication network.
  • S
    Steven MosleyAug 20, 2025
    How to fix poor grounding affecting Kinco Controller performance?
    • E
      Emily BrewerAug 20, 2025
      If poor grounding affects the performance of your Kinco Controller, ensure the motor power cable uses a cable with a shielded net. Connect the motor PE to the ground terminal of the driver, and ensure the driver shell is well grounded.
  • J
    Jennifer HoweAug 30, 2025
    What to do if Kinco Controller communication is interfered with due to power cables?
    • K
      Kristen WhitneyAug 30, 2025
      To prevent communication interference in Kinco Controller due to cable proximity to power cables, communication cables should be routed in separate troughs from the power cables, maintaining a distance of ?20cm.