Chapter 6 Operation modes and control modes
6.4.2 Position flow mode
The position flow mode is used to run a positioning flow with up to 32 tasks in the position mode.
Each task includes information about target position, velocity, acceleration, deceleration, next task
stop / go, next task index, condition to go to next index, total loops and etc.
The Start PosTable function must be configured to a DIN in order to make the position flow
mode available. Other position flow functions are optional.
Table 6-14 Input port function of PosTable mode
If Cond0 ON, Condition0 = PosTable Cond0 (refer to introduction concerning Cond0 ON)
If Cond1 ON, Condition1 = PosTable Cond1 (refer to introduction concerning Cond1 ON)
Entry index of position flow, bit0: PosTable Idx0; bit1: PosTable Idx1; bit2: PosTable Idx2. A bit
which is not configured to DIN means 0.
Table 6-15 OUT functions of the position flow mode
Position flow mode running
In the PC software, click menu item Controller->Control Modes->Position flow Mode in order to
enter position flow parameter settings.
In the multi-segment position mode, the position-to-signal of the 1-7
segment of the Din position is represented by the BCD code composed of
the multi-function signal 0-2.
The command activation can set the bit4 of the control word to activate
the position command. The level change of the DIN position index 0~2 can
also activate the position command. However, when the first segment is
positioned as DIN position 0 after enabling, there is no index signal. The
level change cannot activate the DIN position 0, so the DIN input port
definition command is required to activate.