Kinco FD5P AC series servo
Appendix II: List of Common Object Parameters
160
Other parameter
Name
CANopen
modbus
Commend type
Data type
Description
Use internal
motor library
30410608
-
RWS
Unsigned8
0: Automatically read the motor model
from the encoder and use the
corresponding motor parameters in the
drive motor library (factory default)
1: Support the user to manually input the
motor model and use the motor parameters
corresponding to the motor library in the
driver
Device restart
2FFF0010
2F00
RW
Unsigned16
Starting the bootloader 55AA:
starts the bootloader AA55:
Restarts the driver
Analog
Increment
64101F10
-
RW
Integer16
Used to set the resolution of the
communication magnetoelectric encoder to
the incremental encoder resolution, which
can be set to 4000,8000, and 10000
=0: Do not simulate incremental encoders,
use the resolution of the default motor
>0: Analog incremental encoder resolution
Note: Multi-turn motors do not support analog
increments.