counting value reaches 110,1110 and 2110,it will execute corresponding CV=PV interrupt.
CV=PV
CV=PV
CV=PV
CV=PV
interrupt
interrupt
interrupt
interrupt cyclic
cyclic
cyclic
cyclic execution
execution
execution
execution
CV=PV interrupt cyclic execution is only valid when PV is set as relative value.
If SM141.0 is 0,it means CV=PV interrupt only executes once.When all interrupts finish execution,then it
will stop.If it needs to execute again, it must modify the related registers and execute HSC instruction again.
If SM141.0 is 1,it means CV=PV interrupt is cyclic execution.When the last PV interrupt finishes
execution,PLC will take the current counting value as reference to calculate new value for PV interrupt,then
it will start to compare the counting value and execute CV=PV interrupt and so forth.This process will
execute cyclically.
For example,it sets 3 PV values,such as 10,1000 and 1000.And the current counting value is 100 before HSC
starts,then the value for every interrupt is as following table.
Current
Current
Current
Current counting
counting
counting
counting
value
value
value
value
Interrupt
Interrupt
Interrupt
Interrupt times
times
times
times First
First
First
First value
value
value
value Second
Second
Second
Second value
value
value
value Third
Third
Third
Third value
value
value
value
100 1st time 110 1110 2110
2110 2nd time 2120 3120 4120
4120 3rd time 4130 5130 6130
N time
2.2.4
2.2.4
2.2.4
2.2.4
CV=PV
CV=PV
CV=PV
CV=PV
Envent
Envent
Envent
Envent No.
No.
No.
No.
When it uses single PV mode, the HSC will be fully compatible with K5 (Include CP=PV event No.).
When it uses multiple PV mode, the HSC will assign a new event No. for 32
PV,
as shown in following table.
High
High
High
High speed
speed
speed
speed
counter
counter
counter
counter
Interrupt
Interrupt
Interrupt
Interrupt No.
No.
No.
No. Description
Description
Description
Description
HSC0
64 CV=PV interrupt of 1st PV
65 CV=PV interrupt of 2nd PV
Plus 1
95 CV=PV interrupt of 32nd PV
HSC1
96 CV=PV interrupt of 1st PV
97 CV=PV interrupt of 2nd PV
Plus 1
127 CV=PV interrupt of 32nd PV
HSC2 128 CV=PV interrupt of 1st PV

Other manuals for Kinco KS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kinco KS Series and is the answer not in the manual?

Kinco KS Series Specifications

General IconGeneral
BrandKinco
ModelKS Series
CategoryController
LanguageEnglish

Related product manuals