K5 Installation Instructions
1
3 4
5 6
2
Install 3/8'' Water Supply
7
9
8
etihw
neerg
wolley
der
eulb
to blue
collet
To blue
collet
Cold water pipe run
wall mount using
bracket
under sink
test fit
Tap Mounting Preparation
Tap ConnectionsTap Installation
drill tap mounting hole Ø 13mm
consult with customer, choose one location
Tap Connection to Unit
Air Charge Ta nk Installation
Quickflo Ta nk Installation
(for Air Charge Tank
Installation, skip
to step 9)
tap
rubber gasket
mtg washer
washer
lock washer
nut
3/8'' FNPT
to
3/8'' quick connect
from white collet
etihw
neerg
wolley
der
eulb
to white
collet
etihw
neerg
wolley
der
eulb
to green
collet
to yellow
collet
yellow
green
etihw
neerg
wolley
der
eulb
insert blanking plug
(yellow collet)
green
to green
collet
Water Supply Connection
Unit Placement
OR
under sink
Connect 3/8” Supply pipe to
water mains via isolation valve
Installation should be in accordance with water
bylaws and plumbing regulations.
Minimum feedwater pressure 35psi (2.5 bar)
10
Drain Installation
etihw
neerg
wolley
der
eulb
to red
collet
air gap
turn clockwise
until stops
DO NOT
OVER
TIGHTEN
use ''A'' spacer
(gray)

Other manuals for Kinetico K5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kinetico K5 and is the answer not in the manual?

Kinetico K5 Specifications

General IconGeneral
Filter TypeReverse Osmosis
Daily Production Rate50 gallons per day
CertificationsNSF/ANSI 58
Filter Life6-12 months
Waste Water Ratio1:1

Related product manuals