KING-METER TECHNOLOGY CO., LTD
No.15, Chenchang Road, Beichen Dist.Tianjin,300134,CN
Fax+0086 022 8478 0358 Tel: +0086 022 8478
9
Attached Table 1: Error code definition table
Error code
Definition
PAS level 1 light flashing
Current abnormal
PAS level 2 light flashing
Throttle abnormal
PAS level 1, 2 light
flashing
Motor phase loss
PAS level 3 light flashes
Motor Hall signal is abnormal
PAS level 1, 3 light
flashing
Braking abnormal
All PAS Level light flashing
Communication abnormal
All of the battery
indication lights and Level
lights flashing at the same
time
Power on/off button sticking
All of the battery
indication lights flashes
6km button sticking
All of the battery
indication lights and Level
light flashing alternately
Register error