14
Set Bluetooth password:
Default password is 1234, maximum 8 digits
Command : BTPSW,[Old password],[New password]#
For example:
BTPSW,1234,5555# indicates Password changed from 1234 to 5555
Set IP password
Default is none
Command: PASSWORD,[Old password],[New password]#
PASSWORD,1234# set the password as 1234
PASSWORD,1234,5555# Password changed from 1234 to 5555
UTC,TTTT#
Set time zone:
unit minutes, default UTC+8:00
For example:
UTC,480# Time zone UTC+8:00
UTC,330# Time zone UTC+5:30
UTC,-480# Time zone UTC-8:00
UTC,-210# Time zone UTC-3:30
WY,<A>[,R,M]#
Set towing alarm:
A: On and off1:On 0:Off
Default is off
R: Towing radiusDefault 500 metersRange100-2000 meters
M: Alarm modeOptional
M=0:GPRS,M=1:SMS+GPRS
EgWY,1,100,1# towing alarm onradius 100 meters notification
mode:GPRS+SMS
LEVEL,S#
Set Vibration sensitivity:
S: Sensitivity 1/2/3/4/5 indicates, highest/high/middle/low/lowest
Eg:
LEVEL,1# Sensivity: Highest
LEVEL# Query
ZD,<A>[,M]#
Set vibration alarm:
A=1:Vibration alarm ON A=0:Vibration alarm off Default is off
M: Alarm mode
M=0 Only GPRS,M=1:SMS+GPRS
Eg:
ZD,1,1#
Vibration alarm ON, notification mode: GPRS+SMS
ZD,0# Vibration Alarm Off
ZD#
CORNER,A#
Set cornering compensation angle:
Default is 15 degree, value range 5-180 degree
Eg:
CORNER,15#
CORNER,0#(Delete cornering upload function)