22
Scheme with heat buffer
: 1 – boiler, 2 – controller, 3 - boiler temperature sensor, 4 - outside (weather)
temperature sensor, 5 – boiler pump, 6 – buffer, 7 – lower buffer temperature sensor, 8 – upper buffer
temperature sensor, 9 – burner fan, 10 – burner feeder (stoker), 11 – circulation pump, 12 – mixer pump,
13 – mixer temperature sensor, 14 – mixer valve actuator, 15 - thermostatic 3-way valve for return
protection, 16 – additional B module, 17 – room thermostat, 18 - throttle (poppet) valve, 19 - three-way
thermostatic valve (manually adjustable).
RECOMMENDED SETTINGS:
Service settings → Boiler settings
Service settings → CH and HUW settings
Service settings → Buffer settings
Loading start temperature
Service settings → Buffer settings
Service settings → Buffer settings
Service settings → Mixer 1 settings
Service settings → Mixer 1 settings
Service settings → Mixer 2 settings
Service settings → Mixer 2 settings
Mixer 2 room thermostat *
Service settings → Mixer 2 settings
* when a standard room thermostat with ON-OFF contacts is connected instead of the (17) room
thermostat, select the option for the thermostat = Universal or, if the setting is hidden, do not
need to select any option for the thermostat.
The presented hydraulic scheme does not replace central heating engineering design and may be used for
information purposes only!