27
Scheme of electrical connections of the additional B module: T1 - mixer 1 temperature
sensor type CT4, T2 mixer 2 temperature sensor type CT4, T3 upper buffer temperature
sensor type CT4, T4 lower buffer temperature sensor type CT4, RT1, RT2 standard mixer 1
and 2 room thermostat type NO-NC, RELAY relay 6 VDC, H (mod B) voltage output for alarm
device or reserve boiler, L N PE - mains power 230 VAC, GR earthing, PM1 mixer 1 pump,
PM2 mixer 2 pump, SM1 mixer 1 servomotor, SM2 mixer 2 servomotor, PC circulation
pump, CPU controlling, FU fuse, A main controller, ! connect exclusively with two wires
(do not connect with four wires, as it may lead to damage of the module and main controller).