4. Tighten the crankcase cover bolt slowly, screw to the prescribed torque.
5. Wait for 20 minutes after installation, never refill in oil or start the engine during these 20 minutes.
11.6 Inspection
Inspection of oil alarm
(1) Stand the oil alarm, check the oil alarm output wire and copper earth wire, there should be no
continuity.
(2) Bottom up the oil alarm; check again, there should be continuity.
(3) Bottom up the oil alarm completely in the oil, check the float, there should be no continuity.
Cam height
Standard(mm) Service limit(mm)
29.026-29.086 28.15
58

Other manuals for Kipor IG2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kipor IG2000 and is the answer not in the manual?

Kipor IG2000 Specifications

General IconGeneral
Rated Power1.6 kW
Voltage230 V
Frequency50 Hz
Fuel TypeGasoline
Starting SystemRecoil
Weight22 kg
Engine Type4-stroke, OHV
Noise Level54-59 dB(A)
Continuous Operation Time4 h (at rated load)