Connection rod big end side clearance
Standard(mm) Service limit(mm)
0.1-.0.4 0.8
Oil film clearance of connection rod big end
(1) Wipe off the oil on the surface of crankshaft neck.
(2) Set the plastic wire feeler at the crankshaft neck and install the connection rod. Tighten the bolt to the
prescribed torque, pay attention that don’t revolve the crankshaft. The tighten torque is 8 to 10N.m.
(3) Disassemble the connection rod, measure the plastic wire feeler thickness.
(4) Replace the connection rod if the clearance exceeds the service limit and measure the clearance
again. Grind the crankshaft neck if the new clearance still exceeds the service limit, and use the
connection rod less than the standard valve.
Standard(mm) Service limit(mm)
0.040-0.066 0.120
68

Other manuals for Kipor IG2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kipor IG2000 and is the answer not in the manual?

Kipor IG2000 Specifications

General IconGeneral
Rated Power1.6 kW
Voltage230 V
Frequency50 Hz
Fuel TypeGasoline
Starting SystemRecoil
Weight22 kg
Engine Type4-stroke, OHV
Noise Level54-59 dB(A)
Continuous Operation Time4 h (at rated load)