Provides information on Kistler's global customer service and technical support for product-related inquiries and applications.
Recommends checking equipment packaging for transport damage and reporting issues to the authorized Kistler distributor.
Advises thorough reading of the manual, emphasizes keeping it safe, and notes Kistler's right to alter content without prior notification.
Instructs users not to dispose of old electronic equipment in household waste but to return it to designated disposal points.
Introduces the Type 2516B... as a handy peak-pressure instrument for internal combustion engines up to 4000 1/min.
Details statistical evaluation of 1-100 cycles (Pmax, Pmin, Pav, Psdev, dp/dca max, Speed) and pressure curve (p-t) analysis.
Explains the measurement of cylinder pressure using a sensor, smoothing via a low-pass filter, and battery operation.
Details the Zero Shifter function for setting quiescent voltages and the process of synchronizing with engine speed.
Details device connections (sensor, USB, power) and control elements (On/Off, F1-F3, Menu, Esc, OK, Measure).
Outlines the start-up procedure, factory settings for Measurement and Instrument settings, and how to edit parameters.
Guides users through connecting the sensor, starting measurement, saving data, and assigning it to memory blocks.
Explains the storage of data sets into Memory Block 1 (1-20) and Memory Block 2 (21-40).
Details how to display the instantaneous peak pressure continuously and the importance of disabling auto-off for monitoring.
Describes how to recall single measurements or an overview of 'pav' data from memory blocks.
Provides instructions to delete the entire memory contents via the 'Memory' menu, noting individual measurements cannot be deleted.
Explains the process of transferring stored measurements to a PC via USB, including baud rate adjustments.
Details how measurands are stored and outputted to the USB interface in plain text (ASCII) format.
Explains how to activate the password function to block main menu access and protect parameters from unauthorized changes.
Refers users to specific data sheets for detailed information on sensors and adapters used with the instrument.
Informs users that the PC software for data evaluation is available for free download from the Kistler homepage.
Covers factory calibration certificates for the meter and sensors, and the initial sensitivity setting upon delivery.
Provides a yearly check procedure for the 2516B1 electronics using a sine-wave generator for accuracy.
Recommends professional recalibration of the sensor due to the technical expertise required for static calibration.
Details the procedure for calibrating the 2516B12 electronics and sensor together using a pressure generator.
Lists technical specifications including measuring range, input voltage, sensor supply, and adjustable sensitivity parameters.
Details specifications for the monitor output voltage, gain, error characteristics, and serial interface (USB, Baud rate).
Covers power supply details (battery, external), current consumption, battery life, charge time, and display resolution/characteristics.
Includes operating temperature, moisture, protection rating, dimensions, weight, auto shut-off, and data storage capacity.
Declares compliance with relevant safety (EN 60950) and EMC (EN 61000 series) standards and directives.