Do you have a question about the Kistler 9287C Series and is the answer not in the manual?
Brand | Kistler |
---|---|
Model | 9287C Series |
Category | Measuring Instruments |
Language | English |
Guidelines to ensure user safety during instrument operation and maintenance.
Details the force plate's compliance with CE directives.
Instructions for correct handling and care of the force plate.
Specific handling advice for Type 9287C when using an external amplifier.
Advice on how to effectively read and use this instruction manual.
Information on updates needed if the instrument is modified.
Guidelines for the proper disposal of electrical and electronic equipment.
Explains what the force plate measures and its key capabilities.
Details the different versions of the force plate that are available.
Provides examples of common applications for the force plate.
Explains the core scientific principle behind the force plate's operation.
Describes the physical construction and design elements of the force plate.
Essential points to observe during the installation process.
Basic circuitry and cabling for the entire measuring system.
How to connect the force plate with an external amplifier.
Pinout details for the Type 9287C output connector with external amp.
How to connect the force plate with a built-in amplifier.
Pinout details for the Type 9287CA output connector with built-in amp.
Technical specifications for Cable Type 1759.
Information on the digital control interface and signals.
Guidelines for selecting the appropriate measurement range.
How to use the Operate and Reset functions for accurate measurements.
Specific operating instructions for Balance (Posturography) mode.
Explanation and application of the time constant feature.
Details on the force plate's effective frequency response.
How temperature variations can influence force plate operation.
General explanation of measuring signal polarity.
Polarity of measuring signals in the X and Y directions.
Polarity of measuring signals in the Z direction.
Understanding and adhering to surface pressure limits.
Guidelines regarding instrument recalibration, noting it's typically not needed.
Procedures for performing essential weekly system checks.
How to perform a drift check on each measurement channel.
Instructions for checking the gap around the force plate for debris.
Steps for performing a system check on the force plate.
Verifying force plate setup parameters in the system.
Advisable checks for the regular calibration of the charge amplifier.
Considerations for performing force plate calibration, though not required.
Important checks to ensure reliable operation.
Specific regular checks for the Type 9287C configuration.
Recommended methods for cleaning and sterilization.
Procedures and advice for dealing with a defective force plate.
Physical dimensions and measurement points of the force plate.
Detailed technical specifications for the Type 9287C force plate.
Mechanical and environmental parameters for Type 9287C.
Electrical specifications for the Type 9287C model.
Detailed technical specifications for the Type 9287CA force plate.
General technical specifications for the Type 9287CA model.
Mechanical and environmental parameters for Type 9287CA.
Electrical specifications for the Type 9287CA model.
Technical specifications for the built-in 8-channel charge amplifier.
Information on the accuracy of calculated Center of Pressure (COP) coordinates.
Specific details regarding the Aax error in COP calculation.
Specific details regarding the Aay error in COP calculation.
Algorithm for correcting Center of Pressure errors.
Graphs illustrating the frequency response in different directions.
General overview of the Cartesian coordinate system used.
Details the specific coordinate system used by Kistler.
Details the coordinate system proposed by the ISB.
Formulas for calculating various force plate parameters.