Do you have a question about the Kistler 4703B and is the answer not in the manual?

Kistler 4703B Specifications

General IconGeneral
Sensitivity0.407 mV/ (m/s²)
Operating temperature range-50 to +120 °C
Connector10-32 UNF
TypePiezoelectric accelerometer
Output Connector10-32 UNF
MountingAdhesive or stud
Case MaterialTitanium
Linearity±1% FSO
Transverse Sensitivity< 5%

Summary

Foreword

Introduction

Display

Details the device display elements and their functions.

Keypad Functions

Explains the functions of each button on the device keypad.

Important Information

For Your Safety

Provides essential safety guidelines for operating the Strain Gage Meter Type 4703B.

Electromagnetic Compatibility (EMC)

Details the device's compliance with electromagnetic compatibility standards.

Tips for Using the Instruction Manual

Offers guidance on how to effectively use and maintain the instruction manual.

Nomenclature Used

Explains terms and abbreviations used throughout the manual.

Disposal Instructions for Electrical and Electronic Equipment

Provides instructions for the environmentally sound disposal of the device.

Setting Up Ranges

General

Explains what a range is and its purpose for sensor configuration.

Keypad Functions for Setting Up

Details the keypad operations required for range setup and editing.

Range Parameters

Details parameters for setting up measurement ranges: rated load, sensitivity, overload, averaging, units, and name.

User Defined Units and Settings

Covers user-defined units, password changes, and unit conversion logic.

Device Setup

Configures device parameters like auto power off, backlight duration, and brightness.

Calibration by Load

Calibration Steps and Process

Outlines the step-by-step procedure for performing load calibration.

Calibration Example and Deletion

Provides a calibration example and explains how to delete calibration data.

Zero Load Calibration

Details the ZeroLoad calibration procedure and its implications.

Sensor Connector

Wiring Diagram

Illustrates the pin assignment and signal connections for the sensor.

Error Messages

Error Message Descriptions

Lists common error messages, their descriptions, and potential causes for troubleshooting.

Application Note

Handling Different Sensor Sensitivities

Guidance on creating and calibrating ranges for sensors with varying sensitivities.

Plate Load Test Application

Details using the device for plate load tests according to DIN 18134.

Setup Diagram

Ranges Setup Flow

Visual representation of the setup process for measurement ranges.

Device Setup Flow

Visual representation of the device configuration settings.

Basic Instrument Information

Unpacking

Instructions for inspecting and handling the instrument upon receipt.

Storage

Guidelines for proper storage of the instrument to maintain its condition.

Ordering Key

Details the ordering information and part numbers for the device.

Included Accessories

Lists the items that come standard with the Strain Gage Meter Type 4703B.

Optional Accessories

Lists additional accessories available for purchase to enhance functionality.

Technical Data

Input and Display Specifications

Details input signal characteristics, display resolution, and range.

Power Supply and Environmental Data

Covers power requirements, operating time, and environmental operating conditions.

Performance and Connectivity Specs

Lists linearity, noise, zero drift, interface, dimensions, and protection ratings.