Do you have a question about the Kistler 4703B and is the answer not in the manual?
Sensitivity | 0.407 mV/ (m/s²) |
---|---|
Operating temperature range | -50 to +120 °C |
Connector | 10-32 UNF |
Type | Piezoelectric accelerometer |
Output Connector | 10-32 UNF |
Mounting | Adhesive or stud |
Case Material | Titanium |
Linearity | ±1% FSO |
Transverse Sensitivity | < 5% |
Details the device display elements and their functions.
Explains the functions of each button on the device keypad.
Provides essential safety guidelines for operating the Strain Gage Meter Type 4703B.
Details the device's compliance with electromagnetic compatibility standards.
Offers guidance on how to effectively use and maintain the instruction manual.
Explains terms and abbreviations used throughout the manual.
Provides instructions for the environmentally sound disposal of the device.
Explains what a range is and its purpose for sensor configuration.
Details the keypad operations required for range setup and editing.
Details parameters for setting up measurement ranges: rated load, sensitivity, overload, averaging, units, and name.
Covers user-defined units, password changes, and unit conversion logic.
Configures device parameters like auto power off, backlight duration, and brightness.
Outlines the step-by-step procedure for performing load calibration.
Provides a calibration example and explains how to delete calibration data.
Details the ZeroLoad calibration procedure and its implications.
Illustrates the pin assignment and signal connections for the sensor.
Lists common error messages, their descriptions, and potential causes for troubleshooting.
Guidance on creating and calibrating ranges for sensors with varying sensitivities.
Details using the device for plate load tests according to DIN 18134.
Visual representation of the setup process for measurement ranges.
Visual representation of the device configuration settings.
Instructions for inspecting and handling the instrument upon receipt.
Guidelines for proper storage of the instrument to maintain its condition.
Details the ordering information and part numbers for the device.
Lists the items that come standard with the Strain Gage Meter Type 4703B.
Lists additional accessories available for purchase to enhance functionality.
Details input signal characteristics, display resolution, and range.
Covers power requirements, operating time, and environmental operating conditions.
Lists linearity, noise, zero drift, interface, dimensions, and protection ratings.