7. Test all connections using an approved noncorrosive leak-
detection solution. Bubbles will show a leak. Correct any
leak found
The appliance nameplate is located inside the grill cabinet on the
Record Conversion
In the last page of the Use and Care Guide, write “Converted to
Natural Gas.” Also record the conversion date and the
technician/company that performed the conversion.
Note: Place LP gas parts in plastic parts bag for future use and
keep with pack containing literature.
le
t
hand cabinet side. With a permanent marker, check the box
next to “Natural gas” and mark through “LP-Propane.”
When converting from LP to Natural gas, you will need to
adjust the high flame setting screw for ideal burner flame
height.
1. Remove each control knob for the main burners.
Adjust High Flame Setting Screw
2. Use a flat-blade screwdriver to turn the high flame
setscrew counterclockwise a
roximate 90º.
3. Check that burner operates at the new high flame setting.
It may be necessary to adjust the screw setting slightly
more to get the ideal burner flame height.
21