▶ Installing the Boiler
1. Do not install the boiler in tighty shut area without ventilation or in bathroom
with a lot of moisture. It may cause the critical lack of oxygen or imperfect
combustion.
2. Install the boiler horizontally and solidly on the nonflammables such as
concrete or bricks which can withstand the weight.
3. Do not install the boiler in open veranda or outdoor for the frost protection.
4. Place the boiler in the area with enough space to check and repair it.
5. Use a plug acceptable only for the boiler.
6. Install the boiler 50mm higher than the floor.
▶ Cautions in installing Flue
1. The highest part of flue should be out of wind pressure belt and
not be influenced by rain and wind.
2. When there is a high building or an obstacle within 1M around the flue,
the flue should be Min. 1M higher than the high building.
3. If the flue is placed in a wind pressure belt, the efficiency of the boiler
is getting lower because the imperfect combustion causes soot, and
that leads to safety shut down function, which means the boiler does
not work well.
AIR
SUPPLY
NON-FLAMMABLES
AIR PRESSURE
BELT
CLEANING
HOLE
1m under
1m under
1m under
chimney
1m