m Troubleshooting plan
For faults that are not listed below, please contact the customer service of Scheppach.
Problem Possible cause Remedy Hazard classification
The hydraulic pump will not
start
No voltage Check whether the lines are
supplied with current
Risk of electric shock
This operation must
be carried out by a
maintenance electrician.
The thermal switch of the
motor has switched off
Restart the thermal switch
inside the motor housing
The cleaver column does
not move in
Low oil level Check the oil level and add
more oil if necessary
Danger of contamination
This operation can be
carried out by the machine
operator.
One of the levers is not
attached
Check the attachment of
the levers
Cut danger
This operation can be
carried out by the machine
operator.
Dirt in the guide rails Clean the cleaver column
Motor starts, but cleaver
column does not move in
Motor turns in wrong
direction
Check the motor direction
and adjust it if necessary
Maintenance and repairs
All maintenance work should be carried out by qualified personnel in strict compliance with the present operating instruc-
tions. Before any maintenance work, all the possible precautions measures must be met; switch off the machine and interrupt
the power supply (if necessary, unplug the connector). Affix a label to the machine, which explains the breakdown: “machine
out of commission for maintenance: Unauthorized persons may not stay in the vicinity of the machine and put it into opera-
tion. “