DocumentNo.:KE-4025-06 20/50
Retightenthevalveglandsand/orreplacethegland-packingrings
periodically.
Wherethelinetemperatureexcessivelyfluctuates,connectionsofthevalve
andthepipeflangesmaygetlooseandcauseleakagethroughthegaskets.
Whenleakageisdetected,retightentheflangeboltsandnutsorreplacethe
gaskets.
Thevalvebodymaybefrozenanddamagedinwinter.Drainwaterfromthe
valveoradequatelyinsulatethevalveinadvancewhenfreezingisforecast.
Cloggingofairpassagemayresultinanabnormalsound.Takeappropriate
measuresimmediately.
Anabnormalsoundmaybegeneratedduetogallingofforeignobjectsinthe
valveseat.Replacethedamagedseatsimmediately.
Excessivevibrationmaycauseexternalleakageormalfunction.Provide
appropriatesupportstothepipeandactuator(Fig.12).
ForTypeBSWactuators,lubricatethethreadedpartsofthespindle
periodicallywithKITZstandardgreaseShellAlvaniaEP2topreventfixing
ofthespindletothestopper.
Checktheexpirationdateforuseofthepartialstroketestdevice.Replace
itbeforetheexpirationdate.
Checktheautomatedopen,closeandPSToperationsbeforestartingthe
operationoftheproduct.
Ifanytroubleisdetectedinapartialstroketest,checktheactuatorandthe
valveimmediatelyandreplacedamagedparts.