Instruction
Manual
ENGLISH
www.kleintools.com
For Professionals...Since 1857
®
Instruction
Manual
CL3000
• DATA HOLD
• BACKLIGHT
• RELATIVE
READING
• AUTO / MANUAL
RANGE
• 3-3/4 DIGIT
3999 COUNT LCD
ENGLISH
69204
AUTO
V
DC
CL3000
Instruction Manual
GENERAL SPECIFICATIONS
The Klein Tools CL3000 is a multi-function fork meter. It measures AC / DC
voltage, AC current, resistance, capacitance, frequency, and duty cycle.
It can also test diodes and continuity.
• Operating Altitude: 2000 meters
•
Relative Humidity: 75% max
•
Operating Temperature: 0°C / 32°F to 40°C / 104°F
•
Storage Temperature: -10°C / 14°F to 50°C / 122°F
•
Accuracy Temperature: 18°C / 64°F to 28°C / 2°F
•
Beyond Accuracy Temperature: 0.1*(specified accuracy) / ° C
•
Sampling Frequency: 3 samples per second
•
Jaw size: 12mm max conductor size
•
Dimensions: 7.5" x 2.7" x 1.7"
•
Weight: 7.4 oz.
•
Calibration: Accurate for one year
•
CAT Rating: CAT III 600V
•
Accuracy: ± (% of reading + # of least significant digits)
WARNINGS
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Before each use, verify meter operation by measuring
a known voltage or current.
• Never use the meter on a circuit with voltages that exceed the category based
rating of this meter.
• Do not use the meter during electrical storms, or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Ensure meter leads are fully seated, and keep fingers away from
the metal probe contacts when making measurements.
• Do not open the meter to replace batteries while the probes
are connected.
• Use caution when working with voltages above 60V DC,
or 25V AC RMS. Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock,
replace batteries if a low battery indicator appears.
• Unless measuring voltage or current, shut off and lock out
power before measuring resistance or capacitance.
• Always adhere to local and national safety codes. Use individual protective
equipment to prevent shock and arc blast injury where hazardous live
conductors are exposed.
SYMBOLS
~
AC Alternating Current Warning or Caution
DC Direct Current Dangerous levels
DC/AC Voltage or Current Double Insulated Class II
Ground AC Source
Question and Answer IconNeed help?

Do you have a question about the Klein Tools CL3000 and is the answer not in the manual?

Klein Tools CL3000 Specifications

General IconGeneral
TypeClamp Meter
DisplayLCD
Data HoldYes
Auto Power OffYes
ContinuityYes
Diode TestYes
Safety RatingCAT III 600V
Battery2 x AAA
AC Current Range0 to 400 A
AC Voltage Range600V AC
DC Voltage Range0 to 600 V
Jaw Opening1.3 inches
Dimensions216 x 38 mm

Summary

General Specifications

Safety Warnings

Feature Details and Operation

Feature Details

Overview of key features like data hold, backlight, relative reading, auto/manual range, and LCD.

Function Instructions

Step-by-step guide for using the meter for AC/DC voltage, AC current, and resistance measurements.

Battery Replacement and Power Management

Instructions for replacing the 9V battery and details on the auto power-off feature.

Measurement Functions and Specifications

Frequency and Duty Cycle Measurement

Guides for measuring frequency and duty cycle, including input voltage requirements.

Resistance, Diode, and Continuity Tests

Procedures for testing resistance, diodes (forward/reverse bias), and continuity with buzzer feedback.

Capacitance Measurement

Instructions for measuring capacitance up to 40μF, including safety precautions.

Electrical Specifications

Detailed technical specifications for DC voltage, AC voltage, and AC current measurements.

Advanced Specifications and Support

Detailed Electrical Specifications

Comprehensive specifications for resistance, capacitance, frequency, duty cycle, diode, and continuity tests.

Warranty and Cleaning

Information on the product's two-year warranty and recommended cleaning procedures.

Storage, Disposal, and Customer Service

Guidelines for storing the instrument, proper disposal, and contact information for customer support.

Related product manuals