OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V DC or 600V AC RMS
Diode Test: Approx. 1mA, open circuit voltage ~3.0V DC
Continuity Check: Audible signal <10Ω, max current 1.5mA
Sampling Frequency: 3 samples per second
Auto Power off: After 10 minutes of inactivity.
Overload: "OL" indicated on display
Polarity: "-" on display indicates negative polarity
Display: 3-3/4 digit, 4000 Count, 128 x 64 pixel OLED display
ENGLISH
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
Capacitance
40.00nF 0.010nF ±(4% + 25 digits)
400.0nF 0.100nF
±(4% + 8 digits)
4.000μF 0.001μF
40.00μF 0.010μF
400.0μF 0.100μF
4.000mF 0.001mF ±(10% + 9 digits)
Maximum Input: 600V AC RMS or 600V DC
Temperature
-40° to 104°F
1
°F
±(2.0% + 8 digits)
>104° to 932°F
1
°F ±(1.6% + 5 digits)
>932° to 1832°F
1
°F
±(2.0% + 2 digits)
-40° to 40°C
1
°C ±(2.0% + 4 digits)
>40° to 500°C
1
°C
±(1.5% + 3 digits)
>500° to 1000°C
1
°C ±(1.5% + 2 digits)
Frequency
10Hz to
1MHz
0.001Hz
to 1kHz
±(0.1% + 5 digits)
Duty Cycle
0.1% to 99.9%
(≤100kHz)
0.1%
±1.5%
(Range: 10% – 90%)
Sensitivity: 250mV and < 20V RMS
Maximum Input: 600V AC or 600V DC RMS
Test Equipment Depot - 800.517.8431
99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Klein Tools CL330 and is the answer not in the manual?

Klein Tools CL330 Specifications

General IconGeneral
BrandKlein Tools
ModelCL330
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals