OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V DC or 750V AC RMS
• Diode Test: Approx. 1mA, open circuit voltage ~3.0V DC
• Continuity Check: Audible signal <10Ω, max current 1.5mA
• Sampling Frequency: 3 samples per second
• Overload: "OL" indicated on display
• Polarity: "-" on display indicates negative polarity
• Display: 3-5/6 digit, 6000 Count LCD
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
Capacitance
60.00nF 0.01nF ±(4.0% + 25 digits)
600.0nF 0.1nF
±(4.0% + 8 digits)
6.000μF 0.001μF
60.00μF 0.01μF
600.0μF 0.1μF
6.000mF 0.001mF ±(5.0% + 9 digits)
Maximum Input: 750V AC RMS or 600V DC
Temperature
°F
-148.0° to 32.0°F
0.1
°F
±(1.0% + 5.4°F )
>32.0° to 662.0°F
±(1.0% + 3.6°F )
>662° to 1832°F
1
°F
±(1.0% + 4°F)
Temperature
°C
-100.0° to 0.0°C
0.1
°C
±(1.0% + 3°C)
>0.0° to 350.0°C
±(1.0% + 2°C)
>350° to 1000°C
1
°C
±(1.0% + 2°C)
Maximum Input: 750V AC RMS or 600V DC
Frequency
(Hz)
99.99Hz 0.01Hz
±(0.1% + 5 digits)
999.9Hz 0.1Hz
9.999kHz 0.001kHz
60.00kHz 0.01kHz
Duty Cycle
0.1% to 99.9%
(≤10kHz)
0.1%
±1.5%
(Range: 10% – 90%)
Maximum Input: 750V AC RMS or 600V DC