EasyManuals Logo

Klein Tools CL445 User Manual

Klein Tools CL445
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
4
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V DC or 750V AC RMS
Diode Test: Approx. 1mA, open circuit voltage ~3.0V DC
Continuity Check: Audible signal <10Ω, max current 1.5mA
Sampling Frequency: 3 samples per second
Overload: "OL" indicated on display
Polarity: "-" on display indicates negative polarity
Display: 3-5/6 digit, 6000 Count LCD
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
Capacitance
60.00nF 0.01nF ±(4.0% + 25 digits)
600.0nF 0.1nF
±(4.0% + 8 digits)
6.000μF 0.001μF
60.00μF 0.01μF
600.0μF 0.1μF
6.000mF 0.001mF ±(5.0% + 9 digits)
Maximum Input: 750V AC RMS or 600V DC
Temperature
°F
-148.0° to 32.0°F
0.1
°F
±(1.0% + 5.4°F )
>32.0° to 662.0°F
±(1.0% + 3.6°F )
>662° to 1832°F
1
°F
±(1.0% + 4°F)
Temperature
°C
-100.0° to 0.0°C
0.1
°C
±(1.0% + 3°C)
>0.0° to 350.0°C
±(1.0% + 2°C)
>350° to 1000°C
1
°C
±(1.0% + 2°C)
Maximum Input: 750V AC RMS or 600V DC
Frequency
(Hz)
99.99Hz 0.01Hz
±(0.1% + 5 digits)
999.9Hz 0.1Hz
9.999kHz 0.001kHz
60.00kHz 0.01kHz
Duty Cycle
0.1% to 99.9%
(≤10kHz)
0.1%
±1.5%
(Range: 10% – 90%)
Maximum Input: 750V AC RMS or 600V DC
ENGLISH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Klein Tools CL445 and is the answer not in the manual?

Klein Tools CL445 Specifications

General IconGeneral
BrandKlein Tools
ModelCL445
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals