ENGLISH
Duty
º
F
º
C
m
1
4
2
6
5
7
3
1. AC / DC Voltage:
<
1000V
Features:
REL HOLD MAX/MINRANGE
H. Max / Min Hold
• Press to enter Max / Min mode; the largest and
smallest values will be saved while in this mode.
• Press repeatedly to alternate between the maximum
and minimum readings.
• Press for 2 seconds to return to live reading and
clear the stored maximum and minimum values.
I. Hold / Backlight
• Press to hold the current input on the display.
• Press again to return to live reading.
• Press for 2 seconds to enable/disable lights.
• Using lights drains the battery significantly.
J. K. Battery / Fuse Replacement
• When
indicator is displayed on the LCD,
batteries must be replaced.
• Remove rubber boot, back screw, and replace 2 x AAA batteries.
• This meter uses 440mA / 1000V and 11A / 1000V fast blow fuses.
L. Magnetic Hanger Accessory (Optional, Sold Separately)
• Slide magnetic adapter into protective rubber boot.
• Attach instrument to metal for hands-free use.
M. Bar Graph
• The bar graph shows an approximate analog representation
of a measurement.
• The bar graph responds much faster than the digital display.
• The scale of the bar graph is zero to the maximum reading
of the selected range.
FUNCTION INSTRUCTIONS
• Select AC or DC voltage source.
Duty
PRESS
Duty
º
F
º
C
m
COM
m
FEATURE DETAILS
FEATURE DETAILS
A. B. C.
Use CAT III / CAT IV rated leads.
A. Do not attempt to measure more than 1000V.
B. Do not attempt to measure more than 400mA.
C. Do not attempt to measure more than 10A.
D. Auto Power-Off (Apo)
• Device will power off after 30 minutes non-use.
• Turn the dial or press a button to wake.
• Disabled during Max / Min function.
• Holding Select button while turning on disables Auto Power-Off.
E. Select Functionality Button
• Switch between AC and DC.
• Switch between
Ω, , and .
• Switch between
Hz and %.
• Switch between
°F and °C.
F. Relative Reading Mode
• Press to store current value.
• Display will now show the difference between
the stored and live readings.
• Press again to return to live reading.
G. Auto / Manual Range
• Press repeatedly to cycle through manual ranges.
• Press for 2 seconds to return to auto ranging mode.
•
AT is displayed on LCD only during auto ranging mode.
C
Duty
º
F
º
C
m
COM
m
Temp
REL
RANGE
HOLD
MAX/MIN
SELECT
V
AT
0 10 20 4030
Apo
MM1000
J
G
B
E
F
H
I
K
A
L
M
D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Klein Tools MM1000 and is the answer not in the manual?

Klein Tools MM1000 Specifications

General IconGeneral
BrandKlein Tools
ModelMM1000
CategoryMultimeter
LanguageEnglish

Related product manuals