ELECTRICAL SPECIFICATIONS
CAPACITANCE (AUTO-RANGING)
Range Resolution Accuracy
40.00nF 10pF ±(5.0% + 35 digits)
400.0nF 0.1nF
±(3.0% + 5 digits)
4.000μF 1nF
40.00μF 10nF
400.0μF 100nF
4000μF 1μF ±(5.0% + 5 digits)
Maximum Input: 600V DC or 600V AC RMS
FREQUENCY (AUTO-RANGING)
9.999Hz 0.001Hz
±(1.0% + 5 digits)
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
500.0kHz 100Hz
Sensitivity:
>
8V RMS
Maximum Input: 600V DC or 600V AC RMS
DUTY CYCLE
1% to 99.9%
0.1% ±(1.2% + 2 digits)
Pulse width: 0.1 – 100ms
Frequency width: 5Hz to 10kHz
Sensitivity: >8V RMS
Maximum Input: 600V DC or 600V AC RMS
TEMPERATURE
0° to 1500°F 0.1°F / 1°F ±(2.0% + 9°F)
-18° to 816°C 0.1°C / 1°C ±(2.0% + 5°C)