Dimming actuator
Dimming actuator, 1-gang
Order no.: 2171 00
Dimming actuator, 2-gang
Order no.: 2172 00
Dimming actuator, 4-gang
Order no.: 2174 00
Operating instructions
1 Safety instructions
Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load
is not electrically isolated from the mains even when the output is switched off.
Risk of destruction of the dimmer and load if the set operating mode and load type do not
match. Set the correct dimming principle before connecting or exchanging the load.
Fire hazard. For operation with inductive transformers, each transformer must be fused on the
primary side in accordance with the manufacturer's instructions. Only safety transformers ac-
cording to EN 61558-2-6 may be used.
These instructions are an integral part of the product, and must remain with the end customer.
The connected load and dimmer quality on LED lamps are dependent on the type of lamp
and installation conditions. The connected load of the specified values could vary. We
cannot assume any guarantee for proper function, dimming results and dimming quality.
2 Device components
Figure1: View of dimming actuator 2-gang
1 / 16
32575362 10867485 04.12.2019

Other manuals for KNX GIRA

Questions and Answers

  • G
    goodwinmichaelAug 21, 2025
    Why do my connected LED lamps flicker with the KNX Controller?
    • J
      Jenny MillerAug 21, 2025
      Flickering in connected LED lamps when using the KNX Controller can occur due to several reasons: * The lamps may not be dimmable; check the manufacturer's instructions or exchange the lamps for another type. * The dimming principle and lamps might not optimally match. For HV-LED, check operation in another dimming principle and reduce the connected load if necessary. For LV-LED, check the lamp operating device and replace it if necessary.
  • C
    Christopher LewisAug 23, 2025
    How to fix LED lamp dimly lit when dimmer KNX is switched off?
    • J
      jennifer43Aug 23, 2025
      If an LED lamp remains dimly lit when the KNX dimmer is switched off, it could be that the LED lamp is not optimally suited for this dimmer. To resolve this, you can: * Use a compensation module (see accessories). * Try another type of LED lamp or an LED lamp from another manufacturer.
  • A
    Amanda VelasquezAug 26, 2025
    What to do if the KNX Controller output cannot be operated?
    • B
      billyshafferAug 26, 2025
      If the KNX Controller output cannot be operated, it might be because the output is disabled. In this case, cancel disabling. Another reason could be missing or faulty application software. Check the programming and correct it.
  • L
    Laura KingAug 28, 2025
    Why are my HV-LED lamps too bright in the lowest dimming position with the KNX GIRA Controller?
    • J
      Jennifer LeeAug 28, 2025
      If connected HV-LED lamps or compact fluorescent lamps are too bright in the lowest dimming position, and the dimming range is too small, it could be due to the following reasons: * The set minimum brightness is too high; reduce the minimum brightness. * The HV-LED trailing edge phase control dimming principle does not optimally match the connected lamps; check operation in the "HV-LED leading edge phase control" setting, and reduce the connected load if necessary, or exchange the lamps for another type.
  • S
    Sharon PhamAug 30, 2025
    Why do LED lamps switch off or flicker in the lowest dimming position with my KNX GIRA?
    • R
      Ronald McdowellAug 30, 2025
      If connected LED lamps or compact fluorescent lamps switch off in the lowest dimming position or flicker, the set minimum brightness might be too low. Try to increase the minimum brightness.
  • J
    Jonathan WatsonSep 1, 2025
    What to do if the KNX GIRA Controller output is off and not possible to switch on?
    • S
      Shawn EdwardsSep 1, 2025
      If the KNX Controller output is off and it's not possible to switch it on, the cause may be a bus voltage failure. Check the bus voltage.
  • A
    angelacuevasSep 3, 2025
    Why does my KNX Security Sensors light not switch off despite sufficient ambient lighting?
    • A
      Anne PowellSep 3, 2025
      The device may be set as a motion detector and, therefore, does not evaluate the ambient lighting after reacting. To resolve this, check the programming and set and program the device as a presence detector. Alternatively, the brightness threshold may be set too high. In this case, decrease the brightness threshold using the remote control or parameter setting.
  • I
    iortegaSep 5, 2025
    What to do if KNX Security Sensors light does not switch on despite motion detection and low lighting?
    • M
      Monica LeeSep 5, 2025
      This issue may occur if the wrong function block is active. To solve it, change the function block switch-over. It can also happen if the brightness threshold set is too low. In that case, increase the brightness threshold with the remote control or parameter setting.
  • J
    jmorganSep 7, 2025
    Why does KNX Security Sensors light switch on despite sufficient ambient lighting?
    • J
      john22Sep 7, 2025
      This can occur if the signal function is active, causing the device to operate independently of the brightness. To fix this, check the programming. Alternatively, the device might be operating independently of the brightness. If so, adjust the brightness threshold with the remote control, or adjust the parameter setting for the brightness threshold.
  • D
    Denise CrossSep 9, 2025
    What to do if KNX Security Sensors device responds even without any motion in the detection field?
    • A
      April OlsenSep 10, 2025
      This issue could be due to interference sources in the detection field, or the device settings being too sensitive. To address this, limit the detection field, and remove any interference sources. You can also adjust the sensitivity by one level using the blue sensitivity switch (7) or with the remote control, or reduce the sensitivity in the parameter setting. In small spaces, the sensitivity should be reduced by 1 to 2 levels.

Summary

Safety Instructions

General Safety Precautions

Essential safety guidelines for electrical installation, load matching, and transformer usage.

Operation and Controls

Operation Details

Operation and Installation Guidance

Mounting and General Connection Safety

Guidelines for mounting the device, general electrical connection safety, and environmental considerations.

Electrical Connection Details

Commissioning Procedures

Software Loading and Speed Setting

Procedures for loading addresses, application software, and setting minimum motor speed for speed controller operation.

Technical Data

Troubleshooting

Lamp and Dimming Issues

Troubleshooting for LED/compact fluorescent lamps switching off, flickering, or dimming problems.

Output, Control, and Load Failure Solutions

Solutions for output switching off, overload, short-circuits, load failures, and manual control problems.

Operation and Motor Control Problem Resolution

Addressing issues like non-responsive outputs, flickering luminaires, and motor start/stop problems when used as a speed controller.

KNX GIRA Specifications

General IconGeneral
Protection ClassIP20
Ambient Temperature-5 °C to +45 °C
Communication ProtocolKNX
MountingDIN Rail
Number of ChannelsDepends on model

Related product manuals