Dimming actuator
Dimming actuator, 1-gang
Order no.: 2171 00
Dimming actuator, 2-gang
Order no.: 2172 00
Dimming actuator, 4-gang
Order no.: 2174 00
Operating instructions
1 Safety instructions
Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load
is not electrically isolated from the mains even when the output is switched off.
Risk of destruction of the dimmer and load if the set operating mode and load type do not
match. Set the correct dimming principle before connecting or exchanging the load.
Fire hazard. For operation with inductive transformers, each transformer must be fused on the
primary side in accordance with the manufacturer's instructions. Only safety transformers ac-
cording to EN 61558-2-6 may be used.
These instructions are an integral part of the product, and must remain with the end customer.
The connected load and dimmer quality on LED lamps are dependent on the type of lamp
and installation conditions. The connected load of the specified values could vary. We
cannot assume any guarantee for proper function, dimming results and dimming quality.
2 Device components
Figure1: View of dimming actuator 2-gang
1 / 16
32575362 10867485 04.12.2019

Other manuals for KNX GIRA

Questions and Answers

  • S
    Shelly SmithSep 12, 2025
    Why does KNX Security Sensors light switch off early despite motion detection and low lighting?
    • T
      Tabitha WellsSep 12, 2025
      This problem may happen if the set time is too short. To resolve this, increase the time with the remote control or parameter setting. It could also be a detection problem, where the surface to be monitored is not in the detection field, or furniture or pillars are obstructing the view. In this case, check the detection field and extend the presence detector extension if necessary.
  • R
    Russell FoxSep 14, 2025
    Why does my KNX Security Sensors light not switch on or switches on too late despite motion in the detection field?
    • E
      Emily GrossSep 14, 2025
      This issue can occur if the device is set for alert operation and does not evaluate the first motion impulse detected. To resolve this, check the programming and set and program the device as a motion detector. Alternatively, the evaluation delay may be activated, preventing brief entries into the detection field from being evaluated. If so, correct the programming, and shorten or deactivate the evaluation delay.
  • C
    Chad ParrishSep 16, 2025
    What to do if KNX Security Sensors light switches off briefly and then on again immediately?
    • K
      Kelly WilliamsSep 16, 2025
      This issue can occur if there are luminaires in the detection field. Set the configuration barrier parameter so that cooling light bulbs are not detected. Alternatively, the brightness threshold set may not be reached after switching off. In this case, increase the brightness threshold.
  • W
    William SantiagoNov 18, 2025
    What to do if the KNX Controller output has switched off?
    • C
      Cynthia ManningNov 18, 2025
      If the KNX Controller output has switched off, it could be due to several reasons: * Overheating protection: Disconnect the output from mains and switch off associated circuit breakers. If you are using HV-LED trailing edge phase control, reduce the connected load and consider exchanging the lamps. If you are using HV-LED leading edge phase control, reduce the connected load, check the operation in the "HV-LED trailing edge phase control" setting and consider exchanging the lamps. Allow the device to cool down for at least 15 minutes and ensure proper cooling by providing distance from surrounding devices. * Surge protection: If you are using HV-LED trailing edge phase control, check the operation in the "HV-LED leading edge phase control" setting and reduce the connected load. You ma...

Summary

Safety Instructions

General Safety Precautions

Essential safety guidelines for electrical installation, load matching, and transformer usage.

Operation and Controls

Operation Details

Operation and Installation Guidance

Mounting and General Connection Safety

Guidelines for mounting the device, general electrical connection safety, and environmental considerations.

Electrical Connection Details

Commissioning Procedures

Software Loading and Speed Setting

Procedures for loading addresses, application software, and setting minimum motor speed for speed controller operation.

Technical Data

Troubleshooting

Lamp and Dimming Issues

Troubleshooting for LED/compact fluorescent lamps switching off, flickering, or dimming problems.

Output, Control, and Load Failure Solutions

Solutions for output switching off, overload, short-circuits, load failures, and manual control problems.

Operation and Motor Control Problem Resolution

Addressing issues like non-responsive outputs, flickering luminaires, and motor start/stop problems when used as a speed controller.

KNX GIRA Specifications

General IconGeneral
Protection ClassIP20
Ambient Temperature-5 °C to +45 °C
Communication ProtocolKNX
MountingDIN Rail
Number of ChannelsDepends on model

Related product manuals