A-62051 May 2008 7
Filling the fixer tanks If the Archive Processor is powered up, shut it off before you
remove the fixer tanks or turn off the water. This reduces the
possibility of water overflowing the water jacket later when you reinsert
the tanks.
NOTE: Use proper precautions when using fixer. Review the MSDS for
the fixer.
1. Pull the gear cover back and lift the fixer tanks out of the
Archive Processor. Each fixer tank is labeled with an F.
2. Fill the fixer tanks with Kodak Prostar Plus Fixer, or equivalent, until
the level reaches the fill line (approximately ¼ gallon or 0.65 liters
per tank).
3. Hold the gear cover back and slowly and carefully lower the fixer
tanks into the fourth and fifth position in the Archive Processor.
NOTE: Make sure that the tanks are fully seated and level with the
fill lines toward the rear of the Archive Processor.