A-62051 May 2008 3
Archive Processor 220-240 V Archive Processor 120 V
Water supply
NOTE: An auxiliary hot water heater should be located within 6 m (20 ft) of the
Archive Processor to provide consistent water temperature.
To Mixing Valve:
Hot Water 46°C (114°F) minimum
Cold Water 24°C (75°F) maximum
Pressure 276 to 621 kPa (40 to 90 psi)
To Mixing Valve:
Hot Water 46°C (114°F) minimum
Cold Water 24°C (75°F) maximum
Pressure 276 to 621 kPa (40 to 90 psi)
From Mixing Valve:
Mixed Water 34.5 to 36.5°C (94 to 98°F)
Pressure 207 kPa (30 psi) minimum
From Mixing Valve:
Mixed Water 34.5 to 36.5°C (94 to 98°F)
Pressure 207 kPa (30 psi) minimum
Drain: Minimum 22.7 L/min (6 gal/min)
capacity floor drain or wall drain located a
minimum of 20 cm (8 in.) lower than the
Archive Processor to prevent wash water from
backing up
Drain: Minimum 22.7 L/min (6 gal/min)
capacity floor drain or wall drain located a
minimum of 20 cm (8 in.) lower than the
Archive Processor to prevent wash water from
backing up
Water Consumption: 1.9 L/min (0.5 gal/min)
while processing
Water Consumption: 1.9 L/min (0.5 gal/min)
while processing
Film Widths
16 mm or 35 mm single strand
16 mm dual strand in lengths up to 65.5 m
(215 ft)
16 mm or 35 mm single strand
16 mm dual strand in lengths up to 65.5 m
(215 ft)
Film Lengths and
Thicknesses
30.5 m (100 ft) of 0.14 mm/5.2 mil-thick film
38.1 m (125 ft) of 0.11 mm/4.2 mil-thick film
65.5 m (215 ft) of 0.07 mm/2.7 mil-thick film
30.5 m (100 ft) of 0.14 mm/5.2 mil-thick film
38.1 m (125 ft) of 0.11 mm/4.2 mil-thick film
65.5 m (215 ft) of 0.07 mm/2.7 mil-thick film
Film Transport
Speed
3 m/min. (10 ft/min) 3 m/min. (10 ft/min)
Film Processing
Time
30.5 m (100 ft): 11 minutes
65.5 m (215 ft): 22.5 minutes
30.5 m (100 ft): 11 minutes
65.5 m (215 ft): 22.5 minutes
Process
Duration
Approximately 55 seconds for the self-
threader to exit from the Archive Processor
Approximately 55 seconds for the self-
threader to exit from the Archive Processor
Film Loading
Room-light conditions with camera film spools
only
Room-light conditions with camera film spools

Related product manuals