TP-5606 6/021-4 Specifications
Generator Models 15/20 kW (continued)
15CCO Single-Phase Models 15CCOZ Three-Phase Models
(60/50 Hz) (60/50 Hz)
Rotor field voltage/current readings
at rated voltage (hot)
No load (63 Hz) 19V/5.5 Amps 8V/1.1 Amps.............. ..............................
Full load (60 Hz) 38V/9.0 Amps 20V/2.5 Amps............. .............................
20CCO Single-Phase Models 20CCOZ Three-Phase Models
(60/50 Hz) (60/50 Hz)
Rotor field voltage/current readings
at rated voltage (hot)
No load (63 Hz) 19V/5.5 Amps 8V/1.1 Amps.............. ..............................
Full load (60 Hz) 44V/10.2 Amps 30V/4.3 Amps............. ............................
20CCFO Single-Phase Models
(50 Hz)
Rotor field voltage/current readings
at rated voltage (hot)
No load (53 Hz) 23V/5.0 Amps..............
Full load (50 Hz) 60V/11 Amps.............
Single-Phase Models
Stator output voltages with
separately excited rotor
using 12-volt battery (cold)
1-2, 3-4, 33-44 79V....................
33-55 110V...........................
B1-B2 10V...........................
Three-Phase Models
Stator output voltages with
separately excited exciter field
using 12-volt battery (cold)
1-4, 2-5, 3-6, 7-10, 8-11, 9-12 160V.................................................
B1-B2 21V.....................................................................
V0-V7, V0-V8, V0-V9 160V........................................................
55-66 185V......................................................................
Single-Phase Models Three-Phase Models
Excitation Method Static Excited Rotating Exciter................... ............................
Overbolt Torque 25 ft. lbs. (300 in. lbs.).......................................
Voltage Regulator Type PowerBoostä IIIE PowerBoostä V.............. ..........................
Insulation (Rotor and Stator) Class 155, Epoxy Varnish, Vacuum Impregnated.................
Winding Material Copper.............................................
Bearing (Number and Type) 1, Replaceable Ball..............................
Circuit Protection:
Controller 10-Amp Fuse 10-Amp Circuit Breaker....................... .........................
Optional AC Output Manual-Reset Circuit Breaker.............................
Voltage Regulator 10-Amp Fuse 8-Amp Fuse................ ..............................
Fuel Solenoid 10-Amp Fuse.........................................
** Most ohmmeters will not give accurate readings when measuring less than 1 ohm. The stator can be considered
good if a low resistance reading (continuity) is obtained and there is no evidence of shorted windings
(discoloration). Do not confuse a low resistance reading with a reading indicating a shorted winding.