TP-5964 7/01 7Section 3 Scheduled Maintenance
Service Schedule, Continued
Perform Service at Intervals
Indicated (X)
Reference
Section
Before
Starting
Every
50 Hrs.
or 1
Month
Every
100 Hrs.
or 3
Months
Every
150 Hrs.
or 3
Months
Every
300 Hrs.
or 6
Months
Every
500 Hrs.
or Yearly
INTAKE/EXHAUST SYSTEM
Inspect exhaust system components [ 3.6 X
Replace the air cleaner element 3.5.2 X
Clean the breather pipe 3.5.1 X
ELECTRICAL SYSTEM
Keep the battery charged and in good
condition *
X
Adjust the battery charging alternator
belt tension
3.8
X
(Break-in
period)
X
Check and tighten electrical
connections
X
Verify proper operation of gauges,
if equipped
2.4.3 X
Clean battery cables [
X
ENGINE AND MOUNTING
Check for water, fuel, coolant, and oil
leakage []
X X
Retighten all nuts and bolts
X
(Break-in
period)
X
Check tightness of mounting
bolts/vibromounts
[
X
Check intake/exhaust valve clearance
and adjust as necessary
[
X
Retighten cylinder head bolts [ X
REMOTE CONTROL SYSTEM, ETC.
Check remote control operation 2.4
X
(Break-in
period)
X
Check compartment condition
(water, fuel, exhaust, coolant, or oil
leaks)
X
Test run the generator set 2.3
X
(Weekly)
GENERATOR
Blow dust out of generator [
3.1 X
* Consult battery manufacturer’s instructions.
[ Consult your local distributor/dealer for service.
] Read WARNING found at the beginning of manual regarding moving parts.

Other manuals for Kohler 20EORZ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 20EORZ and is the answer not in the manual?

Kohler 20EORZ Specifications

General IconGeneral
BrandKohler
Model20EORZ
CategoryPortable Generator
LanguageEnglish

Related product manuals