TP-5964 7/016 Section 3 Scheduled Maintenance
3.2 Service Schedule
Perform Service at Intervals
Indicated (X)
Reference
Section
Before
Starting
Every
50 Hrs.
or 1
Month
Every
100 Hrs.
or 3
Months
Every
150 Hrs.
or 3
Months
Every
300 Hrs.
or 6
Months
Every
500 Hrs.
or Year
FUEL SYSTEM
Check the fuel level and fill
as necessary
2.1 X
Check for any abnormal fuel
injection sound
X
(During
operation)
Check the governor operation and
adjust as necessary []
X
Replace the fuel filter 3.4.2
X
(Break-in
period)
X
Clean the fuel injection nozzles/check
the injection spray condition []
X
Check the injection timing []
X
LUBRICATION SYSTEM
Check the crankcase oil level and add
as necessary
3.3.2 X
Replace the oil in the crankcase 3.3.3
X
(Break-in
period)
X
Replace the lube oil filter element 3.3.3
X
(Break-in
period)
X
COOLING SYSTEM
Check the coolant level and fill
as necessary
[
3.7 X
Adjust the water pump belt tension 3.8
X
(Break-in
period)
X
Clean radiator fins and inspect hoses * 3.7 X
Check the thermostat function [
3.7 X
Flush the cooling system [
3.7 X
* Consult operating instructions supplied with vehicle.
[ Consult your local distributor/dealer for service.
] Read WARNING found at the beginning of manual regarding moving parts.