TP-6805 8/1528 Section 2 Scheduled Maintenance
damage caused by overheating, keep the housing
cooling inlets and outlets clean and unobstructed at all
times.
Note: Do not block the generator set cooling air inlets or
mount other equipment above them.
Overheating and severe generator damage may
occur.
Remove all combustible materials from the exhaust
location. Combustible materials include building
materials as well as natural surroundings. Keep dry field
grass, foliage, and combustible landscaping material a
minimum of 2.4 m (8 ft.) from the exhaust outlet.
Periodically inspect the exhaust system components for
cracks, leaks, and corrosion.
D Check for corroded or broken metal parts and replace
them as needed.
D Check that the exhaust outlet is clear.
D Check that all covers, doors, and panels are
undamaged, in place, and locked.
tp6733
1. Air intake
2. Exhaust outlet
1
2
1
REAR VIEW
Figure 2-11 Cooling Air Intake and Exhaust,
Composite Enclosure
GM90210
1. Air intake
2. Exhaust outlet
1
2
1
FRONT VIEW
Figure 2-12 Cooling Air Intake and Exhaust, Metal
Enclosure
2.7 Stepper Motor Coupling
Replace the stepper motor coupling and bushings at the
intervals shown in the service schedule. See the Parts
Catalog for replacement part numbers.
Figure 2-13 shows the location of the coupling
assembly under the air cleaner. Loosen the set screw to
remove the coupling from the motor shaft.
1. Coupling and bushing
1
tp6519
Figure 2-13 Stepper Motor Coupling
tp6518_9
1
1. Coupling
2. Bushing
2
Figure 2-14 Stepper Motor Coupling and Bushing

Table of Contents

Other manuals for Kohler 20RESC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 20RESC and is the answer not in the manual?

Kohler 20RESC Specifications

General IconGeneral
Rated Output (Gasoline)20 kW
Rated Output (LPG)18 kW
Voltage120/240 V
Frequency60 Hz
Fuel TypeGasoline, LPG, Natural Gas
Starting SystemElectric
Warranty5 years limited
Dimensions48.5 in L x 29 in H

Related product manuals