TP-6774 2/14a 71Section 7 Controller
7.13.10 Prime Menu
This menu, if confirmed, allows the user to initiate the
electric fuel pump to prime the fuel system.
OR
Prime the Fuel System
Push To Prime ----> Confirm
Prime? Yes
Confirm?
Prime? No
7.13.11 Volt Select
This menu allows the user to readily change controller
voltage settings.
Note: The generator set output leads require voltage
reconnection. See Section 8.11 for voltage
reconnection.
With the generator set stopped, go to the Volt Select
menu. Then push and hold the pushbutton/rotary
selector dial until the voltage selection starts to flash.
Volt selection is now available. Scroll to the desired
voltage and momentarily press the pushbutton/rotary
selector dial to confirm the voltage selection.
Volt Select
Volt Select: ---->
###/### V # Ph
120/240 V 1 Ph
115/230 V 1 Ph
120 V 1 Ph
240 V 1 Ph
230 V 1 Ph
120/208 V 3 Ph
120/240 V 3 Ph
127/220 V 3 Ph
139/240 V 3 Ph
277/480 V 3 Ph
110/190 V 3 Ph
230/400 V 3 Ph
240/416 V 3 Ph
115/230 V 3 Ph

Table of Contents

Other manuals for Kohler 7-9EFKOZD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 7-9EFKOZD and is the answer not in the manual?

Kohler 7-9EFKOZD Specifications

General IconGeneral
BrandKohler
Model7-9EFKOZD
CategoryMarine Equipment
LanguageEnglish

Related product manuals