If your Kohler Marine Equipment generator has high oil use, replace the gaskets to address external leakage or defective gaskets. Also check compression, as the issue might be worn piston rings or valves.
R
Rodney PhillipsSep 4, 2025
Why does my Kohler 9-11EKOZD Marine Equipment generator have high output voltage?
K
Kevin ClarkeSep 4, 2025
If your Kohler Marine Equipment generator has high output voltage, check and adjust the controller configuration settings and voltage settings. Verify the engine speed using a tachometer or frequency meter and adjust the governor as necessary. Check connections at the stator leads 11 and 44 (for 1-phase models) or leads V7, V8, and V9 (for 3-phase models) and the P2 controller connection to address loose voltage sensing connections.
J
Joel DrakeSep 5, 2025
Why is my Kohler 9-11EKOZD Marine Equipment engine knocks?
K
Kevin HensleySep 5, 2025
If your Kohler Marine Equipment generator is making knocking noises, reduce the load if it is excessive. Check the oil level and add oil if it is low.
K
Katherine CruzSep 6, 2025
What to check if my Kohler 9-11EKOZD generator has no output voltage?
D
dtorresSep 6, 2025
If your Kohler Marine Equipment generator has no output voltage, check for AC voltage on the generator side of the circuit breaker. If AC voltage is present, a problem in the load circuits is causing the line circuit breaker to trip; check for and correct short circuits or overloading on the load side before resetting the circuit breaker. Replace the blown auxiliary winding F1 fuse; if it blows again, check the stator. Check the continuity of the open wiring, terminal, or pin in the buildup circuit.
B
blairtoddSep 6, 2025
How to fix light flicker on my Kohler 9-11EKOZD Marine Equipment?
L
Lori FranklinSep 6, 2025
If your Kohler Marine Equipment generator light flicker, check and adjust the voltage stability (gain) setting using the ADC IId.