10.9
Section 10
Reassembly
10
ȱ Řǯȱ ¢ȱĴȱȱȱȱȱȱȱ
ȱȱȱ¡ȱĚȱǯȱȱȱ
10-33.
Figure 10-33. Attaching Fuel Tank Bracket.
ȱ śǯȱ ȱȱĚ¢ȱȱȱȱȱǰȱ
and check that the module does not come in
contact with the magnet. Recheck the air gap.
6. Connect the kill lead to the ignition module. See
Figure 10-32.
Install Ignition Module
ȱ ŗǯȱ ȱȱĚ¢ȱȱȱȱȱȱ
away from the ignition module legs. Position
the ignition module on the legs with the kill tab
down. See Figures 10-30 and 10-32.
Figure 10-30. Positioning Ignition Module/Magnets
2. Loosely thread the stud in a mounting leg and
ȱ¡ȱĚȱȱȱȱǯȱȱȱ
ŗŖȬřŗǯȱȱȱȱ¢ȱȱȱĚ¢ȱ
and tighten the stud to hold it in place. Rotate the
Ě¢ȱȱȱȱȱȱȱȱ
the module.
NOTE: If the stud for mounting the ignition module
was not kept segregated from the two studs
for mounting the fuel tank, compare their
lengths and choose the short one.
Figure 10-31. Tightening Ignition Module Stud.
4. Set the air gap by placing a 0.254 mm (0.010 in.)
plastic feeler gauge between the magnet and the
module. Loosen the stud and let the magnet draw
the module against the feeler gauge. See Figure
10-32. Torque the fasteners to 10 N·m (88 in. lb.).
Figure 10-32. Feeler Gauge.
Magnets
Ignition
Module
Leg
Kill Tab
Feeler
Gauge
Install Fuel Tank
ȱ ŗǯȱ Ĵȱȱȱȱȱȱȱȱǻȱ
removed) with the two bracket screws. See Figure
10-33. Torque the screws to 4.5 N·m (40 in. lb.).
3. Install the spacer onto the ignition module stud.
See Figure 10-31.
Bracket
Bracket Screws
Bracket Nut
Stud
Hex Flange Screw
Spacer