156 Section 8 Component Testing and Adjustment TP-6356 4/12
Model Engine Freq.
High Coolant
Temperature
Shutdown, °C(°F)
High Coolant
Temperature
Warning, °C(°F)
Low Oil Pressure
Shutdown,
kPa (psi)
Low Oil Pressure
Warning,
kPa (psi)
Gas
25--150REZG
GM 50/60 111 (232) 103 (218)
55 (8) 104 (15)
25--150RZG/RZGB 103 (15) 138 (20)
50--150REZGB/RZGB
55 (8) 104 (15)
80/100REZGD/RZGD
180--400REZX
Doosan
60
111 (232) 103 (218) 55 (8) 104 (15)
180--400REZXB
180--400RZX
50/60
180--400RZXB
200--275RZDB DDC Gas 50/60 103 (218) 99 (210) 103 (15) 138 (20)
400--800RZW Waukesha 50/60 102 (215) 96 (205) 241 (35) 276 (40)
Diesel
20ROZJ
John
Deere
50/60
111 (232) 103 (218) 103 (15) 138 (20)20/30REOZJC 60
20--230REOZJB 50/60
40--60REOZJC
60
113 (236) 111 (232) 124 (18) 152 (22)
80--200REOZJC 111 (232) 103 (218) 103 (15) 138 (20)
50--275REOZJD
113 (236) 111 (232) 124 (18) 152 (22)
80--275REOZJE
80--275REOZJF
125REOZJG
300REOZJ
350--500REOZJ 110 (230) 105 (221) 152 (21) 165 (24)
275/300REOZV
Volvo 50/60
104 (219) 98 (208) 248 (36) 317 (46)
350/400REOZVC
450/500REOZVB
106 (223) 101 (214) 269 (39) 303 (44)
500REOZV
550/600REOZV
550/600REOZVB
200REOZPB DDC S40 50/60 111 (232) 103 (218) 103 (15) 138 (20)
230--300REOZDB
DD/MTU
Series 60
50/60 106 (223) 99 (210) 207 (30) 241 (35)
230--450REOZDD 60
106 (223) 99 (210) 207 (30) 241 (35)350/400REOZDC
50/60
450REOZDB
650--1000REOZDB
DD/MTU
50
102 (216) 97 (207)
393 (57) 441 (64)
60 503 (73) 552 (80)
650--2250REOZDC
50/60
104 (219) 102 (215) 359 (52) 393 (57)
700--1000REOZDD
102 (216) 97 (207) 503 (73) 552 (80)
700--1000REOZDE
1250--2250REOZDC
104 (219) 102 (215) 359 (52) 393 (57)
1250--2250REOZDD
1350--2000REOZDB
50
99 (210) 97 (207)
303 (44) 352 (51)
60 372 (54)
421 (61)
2500/2800REOZD
50/60
393 (57)
2500/2800REOZDB
104 (219) 102 (216) 372 (54)
3000/3250REOZD
600--1000REOZM
Mitsubishi
50/60
103 (218) 99 (210) 276 (40) 379 (55)
600--1000REOZMB
60
750--1000REOZMD
750--1000ROZMC
50/60
1250--2000REOZM
98 (208) 92 (198) 296 (43) 393 (57)
1250--2000REOZMB
60
1250--2000REOZMD
1250--2000ROZMC 50/60
Figure 8-61 Factory Shutdown and Warning Setpoints