TT-1625 7/17c
INSTALLATION INSTRUCTIONS
Original Issue Date: 3/14
Model:
Generator Sets with APM802 Controller; Decision-Makerr 3+, 550, 3000,
3500, 6000, and 8000 Controllers; and KPC 1000 Controller
Transfer Switches with Decision-Makerr MPAC 750, 1000, 1200, and 1500
Controllers
Market: Industrial
Subject: Remote Serial Annunciator (RSA III) Kits (Firmware Version 1.0)
Introduction
RSA III is an annunciator panel offered in several kit
configurations to support Kohler power equipment. The
RSA III is a remote serial annunciator (Figure 1,
Figure 2, and Figure 3) that monitors the condition of
the generator set and/or ATS from a remote location.
The RSA III alerts the operator through visual and
audible signals using LED indication and a horn. An
alarm silence and lamp test switch are included.
The RSA III meets NFPA 110, Level 1 applications that
require remote controls and alarms be powered by a
storage battery such as the engine starting battery. AC
adaptor kit GM62466-KP1 is available when NFPA is
not required.
The front panel decals include areas that can be used to
identify user-selected fault inputs and identify
associated power system equipment.
Figure 1 Remote Serial Annunciator (RSA III)
An RSA III annunciator can be used for a single
generator set (Figure 1) or with a combination of a
generator set and automatic transfer switch(es)
(Figure 2 or Figure 3). In systems using more than a
single RSA III, one must be designated as the master
device to broadcast to additional RSA III annunciators,
designated as slave devices. Up to five RSA III slave
devices can be used with an RSA III master device. All
RSA III annunciators are factory set as the master
device, but can be changed to a slave device using a PC
and SiteTecht software that connects to the RSA III
front panel via a universal serial bus (USB) connection.
The RSA II can be connected with the RSA III provided
that the master remote annunciator is an RSA III.
Figure 2 RSA III with Single ATS Control
Figure 3 RSA III with Four ATS Controls

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Kohler Decision-Makerr 3+ and is the answer not in the manual?

Kohler Decision-Makerr 3+ Specifications

General IconGeneral
BrandKohler
ModelDecision-Makerr 3+
CategoryController
LanguageEnglish

Summary

Installation Instructions

RSA III Features Overview

RSA III LED Indicators

System Monitoring LEDs and Functions

Explanation of LED indicators for system status, faults, and warnings.

Detailed LED Status Descriptions

Descriptions of various LED indicators for faults and status conditions.

Safety Precautions

Generator Set Disabling Procedures

Crucial safety warnings and procedures for generator set and equipment handling.

Installation Procedure

Select a Mounting Location for the RSA III

Surface Mount RSA III Initial Installation

Procedure for surface mounting the RSA III box.

Flush Mount RSA III Initial Installation with Box

Steps for flush mounting the RSA III using the supplied box.

Wire the RSA III

P27 RS-485 Connections (Controller to Master)

Wiring details for RS-485 communication between controller and RSA III master.

P27 RS-485 Connections (Master to Slave)

Wiring details for RS-485 communication between RSA III master and slaves.

P37 3-pin Power Connections

Details on connecting the 12/24 VDC power source to the RSA III.

P41 8-pin Input (EPS/User) Connections

Details on connecting EPS supplying load and user inputs to the RSA III.

Complete the RSA III Final Installation

Configure DEC 3+ Controller

Configure APM802 Controllers

Configure DEC 550 and DEC 6000 Controllers

Configure DEC 3000/3500 Controllers

Configure DEC 8000 Controllers

SiteTechâ„¢ Software Settings

Modbus Settings Configuration

Configuring Modbus parameters like baud rate, slave address, and timeout.