18 TP-7077 3/19
Parameter Name
Battery Type
Range
Default Settings
Description
AGM 12 V
-40 – 0
-30
AGM 24 V
-80 – 0
-60
Gel 12 V
-40 – 0
-30
Gel 24 V
-80 – 0
-60
NiCad 12 V
-40 – 0
0
NiCad 24 V
-80 – 0
0
Output Enable
Active
Inactive
Active
Output Enable is always on and controlled
by the generator controller.
Forced Charge Cycle
Reset
Active
Inactive
Inactive
This feature allows a user to manually trigger
a refresh cycle where the charger goes into
the bulk cycle and cycles through the
charger cycle.
These is a single trigger of the feature. The
value returns to inactive automatically once
the action is triggered.
Default 12 V
13 – 15
14.25
Default 24 V
26 – 30
28.5
FLA 12 V
13 – 15
14.25
FLA 24 V
26 – 30
28.5
AGM 12 V
13 – 15
14.25
AGM 24 V
26 – 30
28.5
Gel 12 V
13 – 15
14.25
Gel 24 V
26 – 30
28.5
NiCad 12 V
13 – 16
14.5
Charger Voltage
Bulk (V)
NiCad 24 V
26 – 32
29
Target bulk voltage setpoint
Default 12 V
13 – 15
14.25
Default 24 V
26 – 30
28.5
FLA 12 V
13 – 15
14.25
FLA 24 V
26 – 30
28.5
AGM 12 V
13 – 15
14.25
AGM 24 V
26 – 30
28.5
Gel 12 V
13 – 15
14.25
Gel 24 V
26 – 30
28.5
NiCad 12 V
13 – 16
14.5
Charger Voltage
Absorption (V)
NiCad 24 V
26 – 32
29
Target absorption voltage setpoint
Default 12 V
13 – 14
13.25
Default 24 V
26 – 28
26.5
FLA 12 V
13 – 14
13.25
FLA 24 V
26 – 28
26.5
AGM 12 V
13 – 14
13.8
AGM 24 V
26 – 28
27.6
Gel 12 V
13 – 14
13.6
Gel 24 V
26 – 28
27.2
NiCad 12 V
12 – 16
14.5
Charger Voltage
Float (V)
NiCad 24 V
24 – 32
29
Target float voltage setpoint
Default 12 V
Not available
Not available
Default 24 V
Not available
Not available
FLA 12 V
14 – 16
15.5
FLA 24 V
28 – 32
31
AGM 12 V
Not available
Not available
AGM 24 V
Not available
Not available
Gel 12 V
Not available
Not available
Gel 24 V
Not available
Not available
NiCad 12 V
Not available
Not available
Charger Voltage
Equalize (V)
NiCad 24 V
Not available
Not available
Target equalize voltage setpoint.
Note: The controller’s high battery voltage
warning voltage shall set 0.2 V higher
then this value to avoid nuisance high
battery warnings while charger
performs the equalize cycle.

Related product manuals