TP-7077 3/19 19
Parameter Name
Battery Type
Range
Default Settings
Description
Default 12 V
1 – 5
2
Default 24 V
1 – 5
2
FLA 12 V
1 – 5
2
FLA 24 V
1 – 5
2
AGM 12 V
1 – 5
2
AGM 24 V
1 – 5
2
Gel 12 V
1 – 5
2
Gel 24 V
1 – 5
2
NiCad 12 V
1 – 5
2
Charger Absorption
Current Termination
Target (A)
NiCad 24 V
1 – 5
2
Target absorption termination setpoint that
controls when the absorption cycle
completes. Loads on the battery controller,
meters, and accessories may prevent the
absorption from completing it cycle causing
an absorption timeout error. The
recommended value is 1 A above the
measure resting load on the battery with all
connected accessories active. Lower values
are acceptable but may result in nuisance
faults.
Default 12 V
1 – 5
2
Default 24 V
1 – 5
2
FLA 12 V
1 – 5
2
FLA 24 V
1 – 5
2
AGM 12 V
1 – 5
2
AGM 24 V
1 – 5
2
Gel 12 V
1 – 5
2
Gel 24 V
1 – 5
2
NiCad 12 V
1 – 5
2
Charger Depleted
Battery Current Limit
NiCad 24 V
1 – 5
2
This setpoint limits charger output current
when the charger detects a depleted battery.
Default 12 V
Not available
Not available
Default 24 V
Not available
Not available
FLA 12 V
1 – 5
2
FLA 24 V
1 – 5
2
AGM 12 V
Not available
Not available
AGM 24 V
Not available
Not available
Gel 12 V
Not available
Not available
Gel 24 V
Not available
Not available
NiCad 12 V
Not available
Not available
Equalize Current Limit
(A)
NiCad 24 V
Not available
Not available
This setpoint limits the charger output in the
equalize cycle to avoid excessive gassing.
Default 12 V
4 – 12
10
Default 24 V
18 – 24
20
FLA 12 V
4 – 12
10
FLA 24 V
18 – 24
20
AGM 12 V
4 – 12
10
AGM 24 V
18 – 24
20
Gel 12 V
4 – 12
10
Gel 24 V
18 – 24
20
NiCad 12 V
4 – 12
10
Charger Depleted
Battery Voltage Target
NiCad 24 V
18 – 24
20
The battery terminal open circuit voltage at
which the charger will consider the battery is
in a depleted state and will enter the
recovery charge cycle and softly starts the
charging process.
Default 12 V
10 – 13
12.8
Default 24 V
20 – 26
25.6
FLA 12 V
10 – 13
12.8
FLA 24 V
20 – 26
25.6
AGM 12 V
10 – 13
12.8
AGM 24 V
20 – 26
25.6
Gel 12 V
10 – 13
12.8
Gel 24 V
20 – 26
25.6
NiCad 12 V
10 – 15
13.5
Charger Return to
Bulk State Voltage
Threshold (V)
NiCad 24 V
20 – 30
27
The measured battery terminal voltage at
which the charger will initiate a charge cycle
at bulk.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler GM87448 and is the answer not in the manual?

Kohler GM87448 Specifications

General IconGeneral
BrandKohler
ModelGM87448
CategoryPortable Generator
LanguageEnglish

Related product manuals