Troubleshooting
6 37 690 01 Rev. --KohlerPower.com
TROUBLESHOOTING GUIDE
When troubles occur, be sure to check simple causes which, at rst, may seem too obvious to be considered. For
example, a starting problem could be caused by an empty fuel tank.
Some general common causes of engine troubles are listed below and vary by engine speci cation. Use these to
locate causing factors.
Condition Possible Cause Solution
No AC output Circuit breaker in OFF position. Switch circuit breaker to ON.
Circuit protector popped out. Press circuit protectors.
Engine not operating at rated RPM. Adjust engine running at normal operating
temperature to 3750 ± 100 RPM.
Circuit breaker or receptacles faulty. Test for voltage at circuit breaker and
receptacles.
Stator is faulty. Test for voltage and resistance.
Brushes are faulty. Test for resistance between brushes and
slip ring.
AVR is faulty. Test for voltage.
Low voltage at stator Field polarity was lost. Flash rotor eld.
Alternator can't output
rated power
Engine not operating at rated RPM. Adjust engine running at normal operating
temperature to 3750 ± 100 RPM.
Overload condition. Calculate electrical power required by
electric appliances (in Watts). Reduce
total wattage of connected electric devices
within application range.
Appliance is faulty. Repair faulty appliance.
Tests
Stator voltage
Remove rear cover and start engine with
no load. Check if stator terminals have
correct voltage.

Other manuals for Kohler PRO 7.5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler PRO 7.5 and is the answer not in the manual?

Kohler PRO 7.5 Specifications

General IconGeneral
BrandKohler
ModelPRO 7.5
CategoryPortable Generator
LanguageEnglish

Related product manuals