EasyManua.ls Logo

Koldwave K6HK144BBA2ACA0 - Troubleshooting Common Issues; Resolving Unit Not Working Problems; Resolving No Cold Air Output Issues

Koldwave K6HK144BBA2ACA0
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16 17
Owners Manual
K6HK144BBA2ACA0 / K6HK144BEA2ACA0
Troubleshoong chart
Symptom Possible Cause(s) Correcve Acon
The unit doesn’t work
1. Check the power supply
to verify that power is
available to the unit
1. Reset the circuit breaker and
restart the unit
2. Verify that the power
cord is connected
2. Connect power cord
No cold air ows from the
cold air outlet
1. Ambient air cannot be
properly cooled if the
lter is dirty and not
regularly cleaned
1. Clean the lter
2. Compressor will not
work if the unit is
turned o and on
quickly.
2. Wait 2 minutes aer unit is
turned o before turning the
unit back on.
3. The ambient air tem
-
perature may be too
high
3. The temperature of the com
-
pressor can be higher when
the ambient temperature is
too high. The compressor will
not work unless the ambient
air temperature is within the
acceptable operang range of
the unit
Water ow can be heard
aer compressor shuts o
No cause Common to hear coolant owing
aer unit shuts o

Related product manuals