Owner’s Manual
K6HK144BBA2ACA0 / K6HK144BEA2ACA0
Specicaons (Connued)
Model No. Indoor Air Flow CFM Refrigerant Type / oz(g)
K6HK144BBA2ACA0 4000 R-410A / 282(8000)
K6HK144BEA2ACA0 4000 R-410A / 278.7(7900)
Safety Devices
Compressor overload protector, An-freezing
thermister, Automac restart (Power interrupon),
Compressor me delay program, High pressure
switch, Hot gas bypass
Features
Temperature control, Self-diagnosc funcon,
Oponal drain pump kit, Washable lters, °C display,
O-mer
PUMP-DOWN
The unit is integrated with “PUMP-DOWN”
funcon. PUMP-DOWN funcon keeps compressor
running for
certain me to protect compressor and other crucial
parts before the unit or compressor is turned o.
PUMP-DOWN funcon acvates,
- When the unit reaches target temperature
- In between cooling mode to heang mode
- In between cooling mode to Fan only operaon
The unit operates in this parcular way to protect the
internal parts.
During PUMP-DOWN cycle, the compressor and fans
will be keep operang even though user turns o the
unit or turns o the compressor.
Please do not forcefully switch o the unit or
compressor during PUMP-DOWN cycle. The unit or
compressor will turn o itself when it is safe for the
unit to do so.