6) Reset seq.: When ON, you can reset the Sequence (pushing the Reset button).
7) Aut. res seq- Automatic Reset Sequence: When ON, the control unit automatically resets after the
end of the sequence. When OFF it is necessary to press OK at the end of each sequence.
OPTION MENU:
1) Language: This option allows to choose among the languages available: English, French, German,
Italian, Spanish and Portuguese.
2) Change password: You can change password (see point 3).
3) Password ON: When YES, you will be asked for the password to enter the menu. Otherwise select NO.
ATTENTION: Password is only asked to enter the menu the first time after switching the unit on.
The default password is: 0000.
4) ESC-OK-RST: Press ESC in case of error. Press OK at the end of a program or to reset a sequence or a
program (see point 7: Reset).
When INT, the operator must press the required key on the front panel.
When EXT, functions can only be enabled through proper connections on the back panel (see paragraph I/O
connections).
When INT+EXT you can press either he button on the front or on the back panel.
5) Unit: You can choose between the following units of measurements: Nm, lbf.in and kgf.cm