3-29
PC210/240-ENG
When deciding the ratio of antifreeze to water, check the lowest ;
temperature in the past, and decide from the mixing rate table given
below.
It is actually better to estimate a temperature about 10
o
C lower when
deciding the mixing rate.
Mixing rate of water and antifreeze
PC210
Min. C -5 -10 -15 -20 -25 -30
atmospheric
temperature F 23 14 5 -4 -13 -22
Amount of
antifreeze l 5.1 6.7 8.0 9.1 10.2 11.1
Amount of
water l 17.1 15.5 14.2 13.1 12.0 11.1
PC240
Min. C -5 -10 -15 -20 -25 -30
atmospheric
temperature F 23 14 5 -4 -13 -22
Amount of
antifreeze l 5.4 7.0 8.4 9.6 10.7 11.65
Amount of
water l 17.4 16.3 14.4 13.7 12.6 11.65
WARNING
Antifreeze is flammable, so keep it away from any flame.
Use city water for the cooling water.
If river water, well water or other such water supply must be used,
contact your Komatsu distributor.
We recommend use of an antifreeze density gauge to control the
mixing proportions.
WARNING
When removing drain plug, avoid pouring coolant on yourself.
24. SERVICE PROCEDURE