2-51
PC210/240-ENG
3. When preheating monitor c flashes, turn the key in starting switch
b to the START position to start the engine.
Ambient temperature Preheating time
Above 0
o
C-
0
o
C to -10
o
C 20 seconds
-10
o
C to -20
o
C 30 seconds
4. When the engine starts, release the key in starting switch b.
The key will return automatically to the ON position.
12. OPERATION