AGMGPK
Printed in Japan9242-4879-11
2001 KONICA MINOLTA SENSING, INC.
SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read
the instruction manual before using the instrument.
Always connect the instrument to the
specified power supply voltage. Improper
connection may cause a fire or electric shock.
Be sure to use the specified batteries. Using
improper batteries may cause a fire or electric
shock.
9
Certificate No : JQA-E-80027
Registration Date : March 12, 1997
Certificate No : YKA 0937154
Registration Date : March 3, 1995
System Diagram
Standard Accessories
*1 Operating temperature/humidity range of products for North America : 5 to 40˚C, relative humidity 80% or less (at 31˚C) with no condensation
Specifications
Optional Accessories
193
69
96
AA-size
battery (x4)
AC Adapter AC-A17
AC Adapter AC-A23
(for Korea)
Vinyl cover
Dust cover CM-A152
Target mask ø3
mm
CM-A147
Target mask ø8
mm
CM-A146
CM-2600d
RS232C cable
IF-A16
CM-S100w
Hard case CM-A148
Dust cover set
CM-A149
Zero calibration box
CM-A32
White calibration plate
CM-A145
d/8 (diffuse illumination, 8-degree viewing ), equipped with simultaneous
measurement of SCI (specular component included)/SCE (specular
component excluded) Conforms to CIE No.15,ISO 7724/1,ASTM E1164,
DIN 5033 Teil7 and JIS Z8722 Condition C standard.
ø52mm
Silicon photodiode array (dual 40 elements)
Diffraction grating
360nm to 740nm
10nm
Approx. 10nm
0 to 175%, resolution: 0.01%
3 pulsed xenon lamps
Approx. 1.5 seconds (approx. 2 seconds for fluorescent measurement)
3 seconds for SCI/SCE (4 seconds for fluorescent measurement)
Alkaline manganese:approx. 1000 measurements
MAV: ø8mm/ø11mm
SAV: ø3mm/6mm (Selectable between MAV and SAV)
Spectral Reflectance:Standard deviation within 0.1% (360 to 380nm within 0.2%)
Colorimetric Value : Standard deviation within ∆E*ab 0.04(Measurement
conditions:White calibration plate measured 30 times
at 10-second intervals after white calibration was performed)
within ∆E*ab 0.2 (MAV/SCI) Average for 12BCRA Series
II
color
tiles compared to values measured with master body.
Instantaneous numerical adjustment (no mechanical adjustment required)
With UV400nm cut filter
Single measurement/automatic averaging of multiple measurements
(auto mode: 3, 5, 8 times/manual mode)
RS-232C standard
2/10 degrees (CIE 1931/2°,CIE 1964/10°)
A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation
is possible using two light sources)
Spectral value/graph, colorimetric value, color difference value/graph, PASS/FAIL result
L*a*b*, L*C*h, CMC (1:1), CMC (2:1), CIE94, Hunter Lab, Yxy, Munsell, XYZ,
MI, WI (ASTM E313), YI (ASTM E313/ASTM D1925), ISO Brightness (ISO 2470),
Density status A/T, WI/Tint (CIE/Ganz), CIE0
0
1700 pieces of data (as SCI/SCE 1 data) * 700 pieces of data in the “ defined in COND.” mode.
* Total of the sample data for the COND and TASK modes and color difference target data
Tolerance for color difference (both box and eliptical tolerances can be set)
4 AA-size battery or AC adapter
69 x 96 x 193mm
Approx. 670g (without batteries)
5 to 40˚C, relative humidity 80% or less (at 35˚C) with no
condensation
0 to 45˚C, relative humidity 80% or less (at 35˚C) with no
condensation
White calibration plate, Target mask ø8mm, Target mask ø3mm ,
RS-232C cable, AC adapter, AA-size battery (x4)
Hard case, Dust cover set, Dust cover,
SpectraMagic
TM
NX
(software), Zero calibration box
Mac OS 10.3.7J illustrator 10J
CM-2600d(E)_back.ai 2006.11.21
Personal Computer
(commercially available)
Color control network by spectrophotometer
High inter-instrument agreement between the
portable CM-2600d spectrophotometer and the
desk top CM-3000 series make it easy to build a
total color control network.
R&D
Quality control
Production
CM-3700d
CM-3600d
Company
B
In-house color control Color control among companies
R&D
Quality
Production
Company
A
R&D
Quality
Production
CM-2600d CM-2600d
Dimensions (Units:mm) CM-2600d
Illumination/
observation system
Sphere Size
Light-receiving element
Spectral separation device
Wavelength range
Wavelength pitch
Half bandwidth
Reflectance range
Light source
Measurement time
Minimum interval
between measurements
Battery perfomance
Measurement/
illumination area
Repeatability
Inter instrument
agreement
UV adjustment
Measurement
mode
Interface
Observer
Illuminant
Display data
Color space/
colorimetric data
Data memory
Tolerance judgment
Power source
Size (WxHxD)
Weight
Operating temperature/
humidity range
(*1)
Storage temperature/
humidity range
Standard
accessories
Optional
Accessories
SpectraMagic
TM
NX
* The specifications and
drawings given here are
subject to change without
prior notice.