Model SRX-101A
OPERATION MANUAL
MEDICAL FILM PROCESSOR
CODE NO. 1052
KONICA CORPORATION
No. 26-2, Nishishinjuku 1-chome, Shinjuku-ku, Tokyo 163-0512, Japan

Other manuals for Konica Minolta SRX-101A

Questions and Answers

  • T
    Todd RiosAug 4, 2025
    Why does my Konica Minolta Medical Equipment show a DEV Temp. Error?
    • A
      Austin PayneAug 4, 2025
      The DEV Temp error on your Konica Minolta Medical Equipment indicates that the heater temperature levels have either risen abnormally above or remained below the preset values for an extended period. To address this, first, press the Power Breaker OFF. Then, check to ensure that the developer is circulating correctly.
  • L
    larsenrachelAug 14, 2025
    What to do if my Konica Minolta Medical Equipment displays a Motor Error?
    • D
      Donna SteinAug 14, 2025
      A Motor Error on your Konica Minolta Medical Equipment typically means the rack drive motor is overloaded. To resolve this: * Press the Power Breaker OFF. * Inspect the rack roller or gear mechanisms for any jammed film or foreign objects.
  • J
    Jonathan WilsonAug 23, 2025
    What to do if my Konica Minolta Medical Equipment displays a Film Sensor Error?
    • S
      Shelia GutierrezAug 23, 2025
      If a Film Sensor Error occurs on your Konica Minolta Medical Equipment, normal operation can be done after error occurring. However, if the error repeats, report it to the Konica service station due to potential solute deposits on the lever.

Summary

Precautions

General Handling Precautions

Safety guidelines for normal operation, covering high voltage, foreign objects, and electrical checks.

Installation Precautions

Safety measures for proper setup, including power supply, cord placement, grounding, and ventilation.

Caution Labels

Operating Procedures

Film Processing

Step-by-step instructions for initiating and performing the film processing cycle.

Inserting Cleaning Film

Procedure for daily insertion of cleaning film to maintain optimal processing quality.

Inserting Exposed Film

Guidelines for loading exposed medical film into the processor for development.

Trouble Shooting

Error Diagnostics

Troubleshooting common motor and temperature errors indicated by panel lamps and alarms.

Trouble Check List

A checklist for diagnosing and resolving common processor operational issues before contacting service.

Service and Maintenance